Ultra-Compact AC/DC Programmable Power Supply
PCR-WEA2R Series
PCR-WEA2R-series
2,900,000円 – 15,900,000円
- Compact size: 6 kVA in 6U (PCR6000WEA2/PCR6000WEA2R)
- Up to 36 kVA in a single unit
- AC output *1: Single-phase/Single-phase three-wire/Three-phase
- DC output: +/-, 100% of rated power
- 100% Regenerative-power capability
(Only ”R” models (PCR-WEA2R) with 3 phase 200 V input or 3 phase 400 V
input. Regeneration on premises only.) - Mix-and-match parallel operation up to 144 kVA Same model set up is not required.*2
- Flexible digital interface: LAN (LXI), USB, RS232C, GPIB (option)
- Power line disturbance simulation features
- Sequence function
- External analog, digital control function (standard)
- Power-saving function
- Output frequency up to 5 kHz
- Output rating: AC 0 to 320 Vrms, DC 0 to ±452 V
*1 For 3 kVA or more, the multi-type can switch between single-phase, single-phase 3-wire, and threephase output (PCR-WEA2). *2 Parallel operation is possible with a maximum of four units of 6 kVA or higher models, and different models can be combined as long as they have the same input voltage and input wiring system.
Line-up
- Open in a new windowZOOM
Product Images Model Price Phase Power capacity[VA] Phase voltage[V] Max. current (L/H range)[A]※1 Frequency[Hz] PCR6000WEA2R
PCR6000WEA22,900,000円 (税込:3,190,000円) Single phase 6k (The spec guaranteed voltage range)
1 to 160/ 2 to 320
(L/H output range)
(Voltage setting range)
0 to 161.0/ 0 to 322.060 / 30 1 to 5000 Three-phase 20 / 10 Single-phase Three-wire 4k PCR12000WEA2R
PCR12000WEA25,500,000円 (税込:6,050,000円) Single phase 12k 120 / 60 Three-phase 40 / 20 Single-phase Three-wire 8k PCR18000WEA2R
PCR18000WEA28,100,000円 (税込:8,910,000円) Single phase 18k 180 / 90 Three-phase 60 / 30 Single-phase Three-wire 12k PCR24000WEA2R
PCR24000WEA210,700,000円 (税込:11,770,000円) Single phase 24k 240 / 120 Three-phase 80 / 40 Single-phase Three-wire 16k PCR30000WEA2R
PCR30000WEA213,300,000円 (税込:14,630,000円) Single phase 30k 300 / 150 Three-phase 100 / 50 Single-phase Three-wire 20k PCR36000WEA2R
PCR36000WEA215,900,000円 (税込:17,490,000円) Single phase 36k 360 / 180 Three-phase 120 / 60 Single-phase Three-wire 24k - Open in a new windowZOOM
Product Images Model Price Power capacity[W] Voltage (nominal)[V] Max. current (L/H range)[A]※2 PCR6000WEA2R
PCR6000WEA22,900,000円 (税込:3,190,000円) 6k (The spec guaranteed voltage range)
±1.4〜 ±226 / ±2.8〜 ±452
(L/H output range)
(Voltage setting range)
-227.5 〜 +227.5 / -455.0 〜 +455.060 / 30 PCR12000WEA2R
PCR12000WEA25,500,000円 (税込:6,050,000円) 12k 120 / 60 PCR18000WEA2R
PCR18000WEA28,100,000円 (税込:8,910,000円) 18k 180 / 90 PCR24000WEA2R
PCR24000WEA210,700,000円 (税込:11,770,000円) 24k 240 / 120 PCR30000WEA2R
PCR30000WEA213,300,000円 (税込:14,630,000円) 30k 300 / 150 PCR36000WEA2R
PCR36000WEA215,900,000円 (税込:17,490,000円) 36k 360 / 180 - Open in a new windowZOOM
Product Images Model Price Phase Voltage (nominal)[V] Apparent power[kVA以下] Current[A以下] PCR6000WEA2R 2,900,000円 (税込:3,190,000円) 3-phase 3-wire 200 V Line voltage 200 to 240 7.8 27 3-phase 3-wire 400 V Line voltage 380 to 480 PCR12000WEA2R 5,500,000円 (税込:6,050,000円) 3-phase 3-wire 200 V Line voltage 200 to 240 15.6 53 3-phase 3-wire 400 V Line voltage 380 to 480 PCR18000WEA2R 8,100,000円 (税込:8,910,000円) 3-phase 3-wire 200 V Line voltage 200 to 240 23.4 80 3-phase 3-wire 400 V Line voltage 380 to 480 PCR24000WEA2R 10,700,000円 (税込:11,770,000円) 3-phase 3-wire 200 V Line voltage 200 to 240 31.2 106 3-phase 3-wire 400 V Line voltage 380 to 480 PCR30000WEA2R 13,300,000円 (税込:14,630,000円) 3-phase 3-wire 200 V Line voltage 200 to 240 39 133 3-phase 3-wire 400 V Line voltage 380 to 480 PCR36000WEA2R 15,900,000円 (税込:17,490,000円) 3-phase 3-wire 200 V Line voltage 200 to 240 46.8 159 3-phase 3-wire 400 V Line voltage 380 to 480
Specifications
Input (AC rms)
Model | Single-phase output | Single-phase/three-phase switchable model | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
PCR1000WEA | PCR2000WEA | PCR3000WEA2 | PCR6000WEA2 | PCR12000WEA2 | PCR18000WEA2 | PCR24000WEA2 | PCR30000WEA2 | PCR36000WEA2 | ||
PCR6000WEA2R | PCR12000WEA2R | PCR18000WEA2R | PCR24000WEA2R | PCR30000WEA2R | PCR36000WEA2R | |||||
Nominal input voltage | 1P2W input model | 100 Vac to 120 Vac / 200 Vac to 240 Vac *1 | – | |||||||
3P3W 200 V input model / 3P3W 400 V input model | – | 200 Vac to 240 Vac (3 phase line voltage) *2 / 380 Vac to 480 Vac (3 phase line voltage) *2 *6 | ||||||||
3P4W input model | – | 380 Vac to 480 Vac (3 phase line voltage) *3 | ||||||||
Phase | Single-phase | Three-phase | ||||||||
Nominal input Frequency | 50 Hz to 60 Hz | |||||||||
Input frequency range | 45 Hz to 65 Hz | |||||||||
Apparent power | 1.4 kVA and less | 2.7 kVA and less | 4 kVA and less | 7.8 kVA and less | 15.6 kVA and less | 23.4 kVA and less | 31.2 kVA and less | 39 kVA and less | 46.8 kVA and less | |
Power factor *4 | 0.95(TYP) | 200 V: 0.97(TYP), 400 V: 0.95(TYP) 3P3W input model / 0.95(TYP) 3P4W input model | ||||||||
Maximum current | 1P2W input model *1 | 17 A / 8.5 A | 32 A / 16 A | 48 A / 24 A | – | |||||
3P3W 200 V input model | – | 27 A | 53 A | 80 A | 106 A | 133 A | 159 A | |||
3P3W 400 V input model | 14 A | 28 A | 42 A | 56 A | 70 A | 84 A | ||||
3P4W input model | – | 14 A | 28 A | 42 A | 56 A | 70 A | 84 A | |||
Hold-up time for power interruption *4 | 10 ms | |||||||||
Protective conductor current *5 | 1P2W input model | 3.5 mA or less | – | |||||||
3P3W 200 V input model | – | 10 mA or less | 15 mA or less | 20 mA or less | 25 mA or less | 30 mA or less | 35 mA or less | |||
3P3W 400 V input model | – | 10 mA or less | 20 mA or less | 30 mA or less | 40 mA or less | 50 mA or less | 60 mA or less | |||
3P4W input model | – | 3.5 mA or less |
*1 100 V/200 V input system (auto select) *2 Models with an “R” in the name (6 kVA or higher) have a three-phase, three-wire input. *3 Models of 6 kVA or more without an “R” in the name have three-phase 4-wire input. *4 At output voltage 100 V/200 V, rated output current, sine wave, load power factor 1, output frequency 40 Hz to 1 kHz *5 At output voltage 100 V/200 V, rated output current, sine wave, load power factor 1, output frequency 45 Hz to 65 Hz *6 For the 400V input model, do not connect to transformer equipment with isolation voltage exceed-ing 300 V. It cannot be connected to a delta-connected power distribution facility with one pole grounded.
Output
Model | Single-phase output | Single-phase/three-phase switchable model | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
PCR1000WEA | PCR2000WEA | PCR3000WEA2 | PCR6000WEA2 | PCR12000WEA2 | PCR18000WEA2 | PCR24000WEA2 | PCR30000WEA2 | PCR36000WEA2 | ||
PCR6000WEA2R | PCR12000WEA2R | PCR18000WEA2R | PCR24000WEA2R | PCR30000WEA2R | PCR36000WEA2R | |||||
Maximum peak current *11 | 4 times the maximum output current | |||||||||
Inrush current capacity *3 | 3 times the rated current (0.07 s) *12 1.4 times the rated current (0.5 s) | 1.4 times the rated current (0.5 s) | ||||||||
Efficiency *10 | 82 %(TYP) | 85 %(TYP) |
100% regenerative-power capability
Model | Single-phase/three-phase switchable model | ||||||
---|---|---|---|---|---|---|---|
PCR6000WEA2R | PCR12000WEA2R | PCR18000WEA2R | PCR24000WEA2R | PCR30000WEA2R | PCR36000WEA2R | ||
Maximum regenerated power *1 | 6 kVA | 12 kVA | 18 kVA | 24 kVA | 30 kVA | 36 kVA | |
Maximum reverse power flow current *1 *2 | 1P2W | 60 A / 30 A | 120 A / 60 A | 180 A / 90 A | 240 A / 120 A | 300 A / 150 A | 360 A / 180 A |
1P3W 3P | 20 A / 10 A | 40 A / 20 A | 60 A / 30 A | 80 A / 40 A | 100 A / 50 A | 120A / 60 A | |
Regeneration efficiency *3 | 85 %(TYP) | ||||||
Output current harmonic distortion | THD: 5 % and less, each harmonic: 3 % and less (2nd to 40th) |
* 1 When the output phase voltage is between 100 Vac and 161 Vac or 200 Vac and 322 Vac, the output current is reduced by the output voltage. When the output frequency is between 1 Hz and 40 Hz, the output current is reduced by the output frequency. The output current is 70 % at 1 Hz. * 2 When the output voltage is 100 V or 200 V and the output frequency is between 40 Hz and 1 kHz (when the current phase is -90 deg to -180 deg or 90 deg to 180 deg relative to the output voltage) *3 When the output voltage is 100 V or 200 V, the output current is the rated value, sine wave, the load power factor is 1, and the output frequency is between 45 Hz to 65 Hz.
Output Voltage Stability (Phase Voltage)
Model | Single-phase output | Single-phase/three-phase switchable model | |||||||
---|---|---|---|---|---|---|---|---|---|
PCR1000WEA | PCR2000WEA | PCR3000WEA2 | PCR6000WEA2 | PCR12000WEA2 | PCR18000WEA2 | PCR24000WEA2 | PCR30000WEA2 | PCR36000WEA2 | |
PCR6000WEA2R | PCR12000WEA2R | PCR18000WEA2R | PCR24000WEA2R | PCR30000WEA2R | PCR36000WEA2R | ||||
Line regulation *1 | Within ±0.1 % | ||||||||
Load regulation *2 | Within ±0.1 V/ ±0.2 V(1 Hz to 100 Hz) Within ±0.3 V/ ±0.6 V(100.1 Hz to 500 Hz) Within ±1 V/ ±2 V(500.1 Hz to 1 kHz) | Within ±0.2 V/ ±0.4 V(1 Hz to 100 Hz) Within ±0.3 V/ ±0.6 V(100.1 Hz to 500 Hz) Within ±1 V/ ±2 V(500.1 Hz to 1 kHz) | |||||||
Output frequency variation *3 | When the output voltage correction function is enabled : Within ±0.3 %(1 Hz to 1 kHz), Within ±10 %(1001 Hz to 5 kHz) When the output voltage correction function is disabled : Within -3 dB(5 kHz) | ||||||||
Ripple noise *4 | ≤ 0.25 Vrms | ||||||||
Ambient temperature variation *5 | ±100 ppm/ °C (TYP) | ||||||||
Total harmonic distortion *6 | 0.3 % and less(1 Hz to 100 Hz), 0.5 % and less(100.1 Hz to 330 Hz), 1.5 %/kHz and less(330.1 Hz to 5 kHz) | ||||||||
Transient response *7 | Response FAST : 40 μs(TYP) | ||||||||
Response speed Tr/Tf *8 | Response FAST : 40 μs(TYP) Response MEDIUM : 100 μs(TYP) Response SLOW : 300 μs(TYP) |
* 1 With respect to changes in the rated range of input voltage. 2 With respect to 0 % to 100 % changes in the rating of output current. When the output phase voltage is between 80 V and 160 V (L range) or 160 V and 320 V (H range) and the load power factor is 1, and the response is FAST. At the output terminal block, when the compensation function is not used. * 3 Voltage variation over 40 Hz to 5 kHz in AC mode with 55 Hz as the reference. When the output phase voltage is between 80 V and 160 V or 160 V and 320 V and the load power factor is 1, and the response is FAST, at the output terminal block. * 4 5 Hz to 1 MHz components in DC mode. * 5 With respect to changes in the operating temperature range. When the output phase voltage is 100 V or 200 V, with no load. * 6 When the output phase voltage is between 80 V and 160 V or 160 V and 320 V and the load power factor is 1, and the response is FAST, at the output terminal block. * 7 When the output voltage is 100 V or 200 V, the load power factor is 1, and the output current changes from 0 A to the rated value and from the rated value to 0 A. * 8 At 10 % to 90 % of the output voltage.
Measurement
Model | Single-phase output | Single-phase/three-phase switchable model | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
PCR1000WEA | PCR2000WEA | PCR3000WEA2 | PCR6000WEA2 | PCR12000WEA2 | PCR18000WEA2 | PCR24000WEA2 | PCR30000WEA2 | PCR36000WEA2 | ||
PCR6000WEA2R | PCR12000WEA2R | PCR18000WEA2R | PCR24000WEA2R | PCR30000WEA2R | PCR36000WEA2R | |||||
Voltage Rms value | Resolution | 0.1 V | ||||||||
Accuracy *1 | DC, 40 Hz to 999.9 Hz : ±(0.3 % of reading +1 V), 1 kHz to 5 kHz : ±(0.5 % of reading +1 V) | |||||||||
Current Rms value | Resolution | 0 to 99.99 A: 0.01 A, 100 to 999.9 A: 0.1 A | ||||||||
Accuracy *1 *2 | 45 Hz to 65 Hz : ±(0.3 % of reading +0.3 % of f.s) DC, 40 Hz to 999.9 Hz : ±(0.6 % of reading +0.6 % of f.s) 1 kHz to 5 kHz : ±(1.2 % of reading +1.2 % of f.s) | |||||||||
Current peak value | Resolution | 0 to 99.99 A: 0.01 A, 100 to 999.9 A: 0.1 A | ||||||||
Accuracy *1 *3 | 4 % of f.s | |||||||||
Active power | Resolution | 1 W *5 | ||||||||
Accuracy *1 *2 *4 | 45 Hz to 65 Hz : ±(0.3 % of reading +0.3 % of f.s) | |||||||||
Apparent power | Resolution | 1 VA *6 | ||||||||
Apparent power | Resolution | 0.01 | ||||||||
Power factor | Resolution | 0.1° | ||||||||
Harmonic measurement | Frequency range (fundamental wave) | 10 Hz to 1 kHz | ||||||||
Upper limit of harmonic analysis | 5th to 50th | |||||||||
FFT data length | 4096 | |||||||||
Measurement items | Rms voltage and current, phase angle, THD | |||||||||
Recommended calibration period | 1 year |
* 1 At ambient temperature of 23 °C±5 °C. * 2 At 10 % to 100 % of maximum rated current, sine wave. * 3 Pulse height of sine wave * 4 At a power factor of 1. * 5 When the measured value is 0 to less than 100 W, the resolution is 0.1 W. *6 When the measured value is 0 to less than 100 VA, the resolution is 0.1 VA.
General
Model | Single-phase output | Single-phase/three-phase switchable model | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
PCR1000WEA | PCR2000WEA | PCR3000WEA2 | PCR6000WEA2 | PCR12000WEA2 | PCR18000WEA2 | PCR24000WEA2 | PCR30000WEA2 | PCR36000WEA2 | ||
PCR6000WEA2R | PCR12000WEA2R | PCR18000WEA2R | PCR24000WEA2R | PCR30000WEA2R | PCR36000WEA2R | |||||
Insulation resistance | Between input and chassis, output and chassis, and input and output | 500 Vdc, 10 MΩ or more | ||||||||
Withstanding voltage | Between input and chassis, output and chassis, and input and output | 1500 Vac / 2150 Vdc, 1 minute | ||||||||
Electromagnetic compatibility *1 *2 | Complies with the requirements of the following directive and standards. EMC Directive 2014/30/EU EN 61326-1 (Class A*3), EN 55011 (Class A*3, Group 1*4), EN 61000-3-2*5, EN 61000-3-3*5 Applicable under the following conditions The maximum length of all cabling and wiring connected to the product must be less than 3 m. | Complies with the requirements of the following directive and standards. EMC Directive 2014/30/EU EN 61326-1 (Class A*3) EN 55011 (Class A*3, Group 1*4) Applicable under the following conditions The maximum length of all cabling and wiring connected to the product must be less than 3 m. | ||||||||
Safety *1 | Complies with the requirements of the following directive and standard. Low Voltage Directive 2014/35/EU*2 EN 61010-1 (Class I*6, Pollution Degree2*7) | |||||||||
Environmental conditions | Operating environment | Indoor use, overvoltage category II | ||||||||
Operating temperature range | 0 °C to +50 °C (32 °F to +122 °F) | |||||||||
Storage temperature range | -10 °C to +60 °C (14 °F to +140 °F) | |||||||||
Operating humidity range | 20 %rh to 80 %rh (no condensation) | |||||||||
Storage humidity range | 90 %rh and less (no condensation) | |||||||||
Altitude | Up to 2000 m | |||||||||
Weight | Models without regeneration function | 18 kg (39.7 lb) | 21 kg (46.3 lb) | 25 kg (55.1 lb) | 43 kg (94.8 lb) | 66 kg (145.5 lb) | 120 kg (264.6 lb) | 130 kg (286.6 lb) | 160 kg (352.7 lb) | 180 kg (396.8 lb) |
200 V input models with regeneration function | – | – | – | 43 kg (94.8 lb) | 67 kg (147.7 lb) | 120 kg (264.6 lb) | 130 kg (286.6 lb) | 160 kg (352.7 lb) | 180 kg (396.8 lb) | |
400 V input models with regeneration function | – | – | – | 46 kg (101.4 lb) | 70 kg (154.3 lb) | 120 kg (264.6 lb) | 140 kg (308.6 lb) | 170 kg (374.8 lb) | 180 kg (396.8 lb) | |
Input terminal | M6 | M5 | 3P3W input model: M8, 3P4W input model: M5 | |||||||
Output terminal | M6 | M5 | M6 | M8 | ||||||
Accessories | Cable tie (4 pcs.), External control(DIGITAL I/O) connector (1 pc.), Heavy object warning label (1 pc.)*Excludes PCR1000WEA, Read This First! (1 copy), Quick Reference(1 sheet), CD-ROM (1 disc), Safety Information (1 copy) |
*1 Does not apply to specially ordered or modified products. *2 Only on models that have the CE marking on the panel. *3 This is Class A equipment. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts. *4 This is Group 1 equipment. This product does not generate and/or use intentionally radio-frequency energy, in the form of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose. *5 This does not apply to the PCR6000WEA2R (3-phase 3-wire 200V input model). *6 This is Class I equipment. Be sure to ground this product’s protective conductor terminal. The safety of this product is only guaranteed when the product is properly grounded. *7 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only nonconductive pollution will occur except for an occasional temporary conductivity caused by condensation.
Output Impedance Setting
Model | Single-phase output | Single-phase/three-phase switchable model | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
PCR1000WEA | PCR2000WEA | PCR3000WEA2 | PCR6000WEA2 | PCR12000WEA2 | PCR18000WEA2 | PCR24000WEA2 | PCR30000WEA2 | PCR36000WEA2 | ||
PCR6000WEA2R | PCR12000WEA2R | PCR18000WEA2R | PCR24000WEA2R | PCR30000WEA2R | PCR36000WEA2R | |||||
L range | 1P | 0 Ω to 2000 mΩ | 0 Ω to 1000 m Ω | 0 Ω to 667 mΩ | 0 Ω to 333 mΩ | 0 Ω to 167 m Ω | 0 Ω to 111 m Ω | 0 Ω to 83 m Ω | 0 Ω to 67 m Ω | 0 Ω to 56 m Ω |
1P3W 3P | – | – | 0 Ω to 2000 mΩ | 0 Ω to 1000 m Ω | 0 Ω to 500 m Ω | 0 Ω to 333 m Ω | 0 Ω to 250 m Ω | 0 Ω to 200 m Ω | 0 Ω to 167 m Ω | |
H range | 1P | 0 Ω to 8000 m Ω | 0 Ω to 4000 m Ω | 0 Ω to 2667 m Ω | 0 Ω to 1333 m Ω | 0 Ω to 667 m Ω | 0 Ω to 444 m Ω | 0 Ω to 333 m Ω | 0 Ω to 267 m Ω | 0 Ω to 222 m Ω |
1P3W 3P | – | – | 0 Ω to 8000 m Ω | 0 Ω to 4000 m Ω | 0 Ω to 2000 mΩ | 0 Ω to 1333 m Ω | 0 Ω to 1000 m Ω | 0 Ω to 800 m Ω | 0 Ω to 667 m Ω |
Output Impedance Setting – Reactance component [Response: FAST]
Model | Single-phase output | Single-phase/three-phase switchable model | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
PCR1000WEA | PCR2000WEA | PCR3000WEA2 | PCR6000WEA2 | PCR12000WEA2 | PCR18000WEA2 | PCR24000WEA2 | PCR30000WEA2 | PCR36000WEA2 | ||
PCR6000WEA2R | PCR12000WEA2R | PCR18000WEA2R | PCR24000WEA2R | PCR30000WEA2R | PCR36000WEA2R | |||||
L range | 1P | 40 μH to 2000 μH | 20 μH to 1000 μH | 13 μH to 667 μH | 7 μH to 333 μH | 3 μH to 167 μH | 2 μH to 111 μH | 2 μH to 83 μH | 1 μH to 67 μH | 1 μH to 56 μH |
1P3W 3P | – | – | 40 μH to 2000 μH | 20 μH to 1000 μH | 10 μH to 500 μH | 7 μH to 333 μH | 5 μH to 250 μH | 4 μH to 200 μH | 3 μH to 167 μH | |
H range | 1P | 160 μH to 8000 μH | 80 μH to 4000 μH | 53 μH to 2667 μH | 27 μH to 1333 μH | 13 μH to 667 μH | 9 μH to 444 μH | 7 μH to 333 μH | 5 μH to 267 μH | 4 μH to 222 μH |
1P3W 3P | – | – | 160 μH to 8000 μH | 80 μH to 4000 μH | 40 μH to 2000 μH | 27 μH to 1333 μH | 20 μH to 1000 μH | 16 μH to 800 μH | 13 μH to 667 μH |
Output Impedance Setting – Reactance component [Response: MED]
Model | Single-phase output | Single-phase/three-phase switchable model | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
PCR1000WEA | PCR2000WEA | PCR3000WEA2 | PCR6000WEA2 | PCR12000WEA2 | PCR18000WEA2 | PCR24000WEA2 | PCR30000WEA2 | PCR36000WEA2 | ||
PCR6000WEA2R | PCR12000WEA2R | PCR18000WEA2R | PCR24000WEA2R | PCR30000WEA2R | PCR36000WEA2R | |||||
L range | 1P | 80 μH to 2000 μH | 40 μH to 1000 μH | 27 μH to 667 μH | 13 μH to 333 μH | 7 μH to 167 μH | 4 μH to 111 μH | 3 μH to 83 μH | 3 μH to 67 μH | 2 μH to 56 μH |
1P3W 3P | – | – | 80 μH to 2000 μH | 40 μH to 1000 μH | 20 μH to 500 μH | 13 μH to 333 μH | 10 μH to 250 μH | 8 μH to 200 μH | 7 μH to 167 μH | |
H range | 1P | 320 μH to 8000 μH | 160 μH to 4000 μH | 107 μH to 2667 μH | 53 μH to 1333 μH | 27 μH to 667 μH | 18 μH to 444 μH | 13 μH to 333 μH | 11 μH to 267 μH | 9 μH to 222 μH |
1P3W 3P | – | – | 320 μH to 8000 μH | 160 μH to 4000 μH | 80 μH to 2000 μH | 53 μH to 1333 μH | 40 μH to 1000 μH | 32 μH to 800 μH | 27 μH to 667 μH |
Output Impedance Setting – Reactance component [Response: SLOW]
Model | Single-phase output | Single-phase/three-phase switchable model | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
PCR1000WEA | PCR2000WEA | PCR3000WEA2 | PCR6000WEA2 | PCR12000WEA2 | PCR18000WEA2 | PCR24000WEA2 | PCR30000WEA2 | PCR36000WEA2 | ||
PCR6000WEA2R | PCR12000WEA2R | PCR18000WEA2R | PCR24000WEA2R | PCR30000WEA2R | PCR36000WEA2R | |||||
L range | 1P | 240 μH to 2000 μH | 120 μH to 1000 μH | 80 μH to 667 μH | 40 μH to 333 μH | 20 μH to 167 μH | 13 μH to 111 μH | 10 μH to 83 μH | 8 μH to 67 μH | 7 μH to 56 μH |
1P3W 3P | – | – | 240 μH to 2000 μH | 120 μH to 1000 μH | 60 μH to 500 μH | 40 μH to 333 μH | 30 μH to 250 μH | 24 μH to 200 μH | 20 μH to 167 μH | |
H range | 1P | 960 μH to 8000 μH | 480 μH to 4000 μH | 320 μH to 2667 μH | 160 μH to 1333 μH | 80 μH to 667 μH | 53 μH to 444 μH | 40 μH to 333 μH | 32 μH to 267 μH | 27 μH to 222 μH |
1P3W 3P | – | – | 960 μH to 8000 μH | 480 μH to 4000 μH | 240 μH to 2000 μH | 160 μH to 1333 μH | 120 μH to 1000 μH | 96 μH to 800 μH | 80 μH to 667 μH |
Limit Values and Protection Functions (Common Specification)
Setting range | Resolution | |||
---|---|---|---|---|
Voltage protection | AC voltage upper limit AC voltage lower limit | 0.0 V to 322.0 V | 0.1 V | |
DC voltage upper limit DC voltage lower limit | -455 V to 455 V | 0.1 V | ||
Output overvoltage protection(OVP) | Rms value | 14.0 V to 500.5 V | 0.1 V | |
Positive peak value Negative peak value | 14.0 V to 500.5 V -500.5 V to -14.0 V | 0.1 V | ||
Power module overvoltage protection | Fixed | – | ||
Output undervoltage protection (UVP) | 0.0 V to 500.5 V | 0.1 V | ||
Frequency protection | Frequency upper limit Frequency lower limit | 1 Hz to 5000 Hz 500 Hz LMT model: 1 Hz to 500 Hz (Three-phase output) | 0.01 Hz (1.00 Hz to 100.0 Hz), 0.1 Hz (100.0 Hz to 1000 Hz), 1 Hz (1000 Hz to 5000 Hz) | |
Current protection | Current limit *1 | Maximum output current × 0.1 to maximum output current × 1.1 | 0.01 A (0.35 A to 100.0 A), 0.1 A (100.0 A to 1000 A) | |
Positive peak current limit Negative peak current limit *2 | Maximum output current × 0.1 to maximum output current × 4.2 | |||
Overheat protection | Power module overheat protection | Fixed | – | |
Fan error | Fixed | – | ||
Overload protection | Rated current or current limit | Current limit resolution | ||
Independent operation detection | Fixed | – | ||
Sensing error detection | ±(10 % +10 V) with respect to the output terminal voltage | – |
*1 The current that can actually be supplied is 1.1 times the rated current or the current limit, whichever is less. *2 The current that can actually be supplied is the maximum peak current or the current limit, whichever is less.
Options
Input power cable
For PCR6000WEA2R (3-phase 3-wire 200 V/400 V input)/PCR12000WEA2R (3-phase 3-wire 400 V input)
For PCR12000WEA2R (3-phase 3-wire 200V input)
For PCR18000WEA2R (three-phase 3-wire 200V input) / PCR30000WEA2R/36000WEA2R (three-phase 3-wire 400V input)
For PCR18000WEA2R (three-phase 3-wire 400 V input)
For PCR24000WEA2R (three-phase 3-wire 200 V input)
For PCR24000WEA2R (three-phase 3-wire 400 V input)
For PCR30000WEA2R/36000WEA2R (3-phase 3-wire 200V input)
6 kVA single-phase/three-phase output transformer
The device is designed to perform high-voltage tests on avionics equipment. Thanks to the built-in step-up transformer, it can handle 360 V DO-160 abnormal tests.
Connector for external control
DIGITAL I/O
ANALOG I/O
Parallel-operation cable
Length: 1 m.
Power signal cable
Length: 1 m.
GPIB Interface
Base Hold Angles
Rack Mount Bracket
For PCR6000WEA2(R)
For PCR12000WEA2(R)
Output Terminal Box
● 2 lineups depend on output power, “6 kVA to 18 kVA model” and “24 kVA to 36 kVA model”.
● Toggle between “single-phase” or “single-phase 3-wire/3-phase” output terminal using main unit switch.
Output terminal box (18 kVA)
Output terminal box (36 kVA)
Software
More convenient and easy to use! Appliquation software to help you with your exams
Product Catalog
2D CAD
Ver.3.xx model
PCR6000WEA2R
PCR12000WEA2R
PCR18000WEA2R/PCR24000WEA2R
PCR30000WEA2R/PCR36000WEA2R
Ver.4.xx model
PCR6000WEA2R
PCR12000WEA2R
PCR18000WEA2R/PCR24000WEA2R
PCR30000WEA2R/PCR36000WEA2R