Safety Testers
SAFETY TESTER
Top brand of safety-related testing equipment|KIKUSUI TOS Series
The TOS Series has been adopted by many electrical and electronic equipment manufacturers in Japan and overseas as the top brand of safety-related testing equipment that complies with the Electrical Appliance and Material Safety Law as well as safety standards around the world. When introducing testing and inspection equipment for the laws and standards of various countries, please consider the reliable and proven TOS Series from Kikusui Electronics Industry.
Electrical Safety Multi-analyzer TOS9300 Series
- AC/DC Hipot Tester
- Insulation Resistance Test
- Partial discharge test
- Ground Bond tester
- Leakage Current Test
The TOS9300 series is an electrical safety standard test multi-analyser that can perform several types of safety tests on electronic equipment/components.Types of safety tests include DC Hipot Tester, AC Hipot Tester, Insulation Resistance Test, Ground Bond Test, Leakage Current Test (contact current test, protective conductor current test, patient leakage current test), Partial Discharge Test are available.The models are configured according to the combination of tests required, so that a single unit can handle a variety of safety tests without waste.It is suitable for research and development facilities, quality assurance testing and testing facilities of standards certification bodies, as well as production line facilities.
TOS5300 series
New low-cost standard model that provides thorough operability, reliability and safety.
The TOS5300 series is among the four tests required to ensure the safety of electrical products, Withstanding voltage test and Insulation resistance test. Output voltage is 5kV/100mA (AC) and 6kV/10mA (DC), enabling Withstanding voltage/Insulation resistance testing of electronic equipment and components in accordance with the requirements of national safety standards such as IEC, EN, UL, VDE, JIS, and the Electrical Appliance and Material Safety Law. In addition, the newly developed switching amplifier improves test voltage stability, maintaining constant Output voltage even when AC line voltage or frequency changes, enabling stable testing even in regions with unstable power supply environments. A full range of functional equipment is provided to meet various testing needs. This is a low-cost standard model that is thoroughly designed for ease of operation, reliability, and safety.
- AC Withstanding Voltage (AC Hipot)
- Insulation resistance
A new standard for Hipot Insulation resistance testing Applied to World-Wide input voltage
- The PWM amp system provides highlystable output
- 5kV/100mA (500 VA)AC Hipot test
- Measurement range of insulation resistance testing : 25V to 1000V(7 steps), 500V or greater, up to 5.00GΩ Insulation Resistance test
- High accuracy measurement ±1.5% of reading (at 500V or more for voltmeter and 1mA or more for ammeter)
- Rise Time/Fall Time Control Function
- AC Withstanding Voltage (AC Hipot)
- DC Withstanding Voltage (DC Hipot)
5kV / Max. output 500VA (AC), 6kV / Max. output 50W (DC) Hipot Tester
- The PWM amp system provides highlystable output
- 5kV/100mA (500 VA)AC Hipot test
- Max. output-voltage of DC hipot testing : 6kV / Max. output 50W
- High accuracy measurement ±1.5% of reading (at 500V or more for voltmeter and 1mA or more for ammeter)
- Rise Time/Fall Time Control Function
- AC Withstanding Voltage (AC Hipot)
AC Hipot Tester with 5kV/500VA Max. output
- The PWM amp system provides highlystable output
- 5 kV/100 mA (500 VA) AC Hipot test
- High accuracy measurement ±1.5% of reading (at 500V or more for voltmeter and 1mA or more for ammeter)
- Rise Time/Fall Time Control Function
- AC Withstanding Voltage (AC Hipot)
A Perfect AC Hipot Test solution, with 500 VA capacity and equipped PWM amplifier at very affordable investment
- Highly-stable output with PWM Amp System
- 5 kV/100 mA (500 VA) AC Hipot test
- High accuracy measurement ±1.5% of reading (at 500V or more for voltmeter and 1mA or more for ammeter)
- Rise Time/Fall Time Control Function
- AC Withstanding Voltage (AC Hipot)
- DC Withstanding Voltage (DC Hipot)
Exclusive model of TOS Series having AC, DC10 kV output
- Compliant with various safety standards
- Equipped with remote control function
- DC output also available
- Various signal output functions
- Digital voltmeters and ammeters
- ※Discontinued / Limited Stock
TOS7200 series
- Insulation Resistance Tester
Complied with the test voltage -25 VDC to -1000 VDC of the JIS C 1302-2002
- Resistance measurement range: 0.01MΩ to 5000MΩ
- Provided with the discharge function
- Equipped with the window comparator
- Hold function (which holds the measured resistance at the end of testing while PASS judgment is being output)
- Provided with the timer function
- PID Insulation Tester
Capable of continuous long-term operation for applying the high voltage required to the PID affect of the PV module
- The PID insulation tester (TOS7210S) is designed based on the insulation resistance tester (TOS7200) to carry out the evaluation of the PID (Potential Induced Degradation) effect of the PV module precisely and efficiently. Being equipped with the output ability of 2000 V and the ammeter with nA resolution as well as a polarity switching function, the TOS7210S is also applicable not only to the PID evaluation but also the evaluation of the insulators that requires a high sensitivity of measurement. The tester is equipped with the panel memory that is externally accessible and RS232C interface as standard; it can be flexibly compatible with the automated system.
- ※Discontinued / Limited Stock
TOS6210 / TOS6200A
- Max.60A
- Ground Bond Test
Supports UL60950-1(40A / 60A) testing – New Standard for Information Technology Equipment (ITE)
- Test current value: 6 A to 60 A AC / Resistance value: 0.001 Ω to 0.600 Ω
- Voltage drop-based judgment function
- Offset cancelling function
- Stores 100 test conditions in memory
- Incorporates test conditions into program
- Max.30A
- Ground Bond Test
Suitable design for the automated ground bond testing adopted with the constant current method.
- Test current value: 3 A to 30 A AC/Resistance value: 0.001 Ω to 1.200 Ω
- Can be determined by resistance and voltage drop
- Offset cancelling function
- Stores 100 test conditions in memory
- Incorporates test conditions into program
TOS3200
- Leakage Current Tester
Complying with various safety standards for general electrical equipment, this tester is used for touch current and protective conductor current tests!!
- Capable of measuring leakage current in three modes
- Eight built-in measurement circuit networks
- Up to 30 mA for RMS measurement
- Easy-to-understand operation
- Enables the continuous execution of tests
- Capable of saving test results
- 51 types of standard test conditions are preset
- Lets you manage the calibration time limit
Residual charge measuring device
Residual charge measurement made easy and reliable
In the past, residual charge measurements were carried out manually by pulling out the plug, but with this unit, simply connect the plug of the product in question to the multi-outlet of the device, set the timer and press the START button, the power supply is cut off at peak voltage and the voltage between the plug blades after the set time has elapsed is displayed on the meter.The meter displays the voltage between the plug blades after the set time has elapsed.It also has a terminal for waveform observation on an oscilloscope, which is useful for recording waveforms. *The voltage between the plug blades is to be measured at the maximum value.One measurement is considered sufficient if the plug can be pulled out at the peak of the supply voltage.
- Residual charge measuring device
Easy and reliable residual charge measurement without cumbersome plug pulling
- Complies with the Electrical Appliance and Material Safety Law, IEC60950-1, IEC60601-1, IEC60335-1, IEC60065, etc.
- This unit (SPEC40509) requires our AC power supply (PCR-L/LA/LE/W/WE series).
- Automatic shut-off at peak voltage; only one measurement required.
- With switch for switching between voltage measurement L-N/L-G/N-G.Voltage measurement between L-N, L-G and N-G is possible by using the switch between voltage measurement. *Use special jig for measurement between N and G (standard accessory).
Options for Electrical Safety Testers
- Options
A list of options for safety-related test equipment is available
- Test lead, Test probe
- Remote control
- Multi Outlet
- Warning light unit, Terminal unit
- Rack Mount Bracket