KES7714

KES7714

  • ISO 7637-2 Pulse 1 waveform/24 V, bipolar output type CDN100A
  • Compact modular cabinet
  • Output terminals provided at a height of 50mm above the floor level as specified in the ISO 7637-2 standard
  • Dedicated software for condition setting and tester control

Request for Quotation Save to myKIKUSUI
SKU: KES7714
  • Outline
  • Options
  • Downloads

Outline

ISO7637-2 Pulse1-12V

KES7711A, KES7713B and KES7714 generate test pulses 1 required by the ISO and SAE standards. Test pulse 1 is used to simulate the transient phenomenon that occurs when the power supply is cut off from the inductive load.

パルスユニット1-24V

ModelKES7713BKES7714
Pulse unit 1External-connect type
Peak voltage (Us)±20V to ±700V, in steps of 0.1V
Output impedance (Ri)20Ω (SAE), 50Ω (ISO)
Rise time (tr)1µs(+0µs, -0.5µs(SAE), 3µs(+0µs, -1.5µs(ISO)
Pulse width (td)1000 µs ± 200 µs at No Load / 50 Ω Load
Repetition interval (t1)0.5s to 99s, in steps of 0.1s
DC cut time (t2)1 ms to 200 ms, in steps of 0.1 ms
Surge delay time (t3)Less than 100 µs
CDN capacity60VDCmax 50Amax60VDCmax 100Amax
Driving power100 VAC to 240 VAC 50/60 Hz
Power consumption200VA
Dimensions440(17.32")W×280(11.02")H×595(23.42")D mm
WeightApprox. 40 kg(88.18lbs)Approx. 42 kg(92.59lbs)

■ DC cut time can be set within a range of 1 ms to 200 ms. ■ Since it also outputs positive polarity waveforms whose polarity has been reversed, it supports not only ISO standards but also independent standards of automobile manufacturers as well. ■ Output impedance: Since 20 Ω and 50 Ω can be selected, it supports ISO7637-2.2004 standards and SAE J1113 standards.

pulse

Downloads

Product Catalog

Please feel free to contact us with any questions or concerns.

Download a Product Catalog View List