PLZ2004WB
490,000円 (税込:539,000円)
- Operating Voltage: 1.5 V to 150 V
- Current: 400 A
- Power: 2000 W
- Input Power Voltage Range: 100 V to 240 VAC (90 V to 250 V AC), single-phase continuous
- Power Consumption: 200 VA max
- Weight: Approx. 23 kg
- Dimensions: 429.5 (W) [455] × 128 (H) [150] × 550 (D) [600] mm
Out of stock
Product Overview
Capacity Expansion Booster
To achieve high capacity at a low cost, the PLZ1004W has the PLZ2004WB as a booster. Up to 4 boosters can be connected in parallel with one PLZ1004W as the master unit (up to 9 kW, 1800 A). Optional parallel cables PC02-PLZ-4W and PC01-PLZ-4W are required for connection depending on the number of units connected. *The PLZ2004WB is dedicated to the PLZ1004W. It cannot be used in conjunction with other models.
Number of parallel connected units and capacities (maximum currents and maximum voltages)
| PLZ2004WB | Max. currents | Max. voltages |
|---|---|---|
| 1 unit | 600A | 3000W |
| 2 units | 1000A | 5000W |
| 3 units | 1400A | 7000W |
| 4 units | 1800A | 9000W |
Specifications
Rating
| Operating voltage | 1.5 Vdc to 150 Vdc *1 |
|---|---|
| Current | 400 A |
| Power | 2000 W |
| Current setting accuracy *2 | ±(1.2 % of set + 1.1 % of f.s) *3 |
*1 Minimum voltage at which the current starts flowing to the PLZ2004WB is approx. 0.3 V. The PLZ2004WB detects no signal at an input voltage less than or equal to approx. 0.3 V and an input current less than or equal to approx. 1 % of the range rating. If the input voltage is gradually increased from 0 V, no current will flow until 0.3 V is exceeded. Once a current greater than or equal to 1 % of the range rating starts flowing, the current can flow at voltages less than equal to 0.3 V. *2 Condition in which the booster is connected to the master unit. *3 M range applies to the full scale of H range.
General Specifications
| Environment | Operating temperature range | 0°C to 40°C (32°F to 104°F) |
|---|---|---|
| Operating humidity range | 20 % – 85 % RH (without condensation) | |
| Storage temperature range | -25°C to 70°C (-13 °F to 158 °F) | |
| Storage humidity range | 90 % RH or less (without condensation) | |
| Input voltage range | 100 VAC – 240 VAC (90 VAC – 250 VAC) Single phase, continuous | |
| Input frequency range | 47 Hz – 63 Hz | |
| Power | 200 VAmax | |
| Inrush current | 35 A | |
| Insulation resistance | Primary – input terminal Primary – chassis Between input terminals and chassis | 500 VDC, 30 MΩ or more (ambient humidity of 70 % RH or less) |
| Withstanding voltage | Primary – input terminal Between primary and chassis | No abnormalities at 1500 Vac for 1 minute. |
| Weight | Approx. 24 kg(52.91 Ib) | |
| Accessories | Power cord: 1 (wire length 2.4 m), load input terminal cover: 2 (with auxiliary band), load input terminal screw set: 2 pairs (bolt, nut, spring washer), heavy duty warning seal: 1 sheet, operating instructions: 1 booklet | |
| Safety *1 | Complies with the requirements of the following directive and standard. IEC61010-1:2001(Class I *2 , Pollution degree 2 *3) | |
*1 Does not apply to specially ordered or modified PLZ-4Ws. *2 This is a Class I equipment. Be sure to ground this product’s protective conductor terminal. The safety of this productis only guaranteed when the product is properly grounded. *3 Pollution is addition of foreign matter (solid, liquid or gaseous) that may