Variable Regulated DC Power Supply
PAD-LA Series
PAD-LA
590,000円 – 1,150,000円
- Use large LED monitor with high visibility for 4 digits display
- Output and Set Switch
- Putting together of the mode setting switches
- Control terminals
- OCP (Over Current Protection circuit)
- Output monitoring
*Limited stock due to end of production.
Specifications
Type Ⅲ
Open in a new windowZOOM
Specifications | Output | Ripple | Line regulation | Load regulation | Dimensions | Weight | AC input | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Model | CV | CC | CV | CC | CV | CC | CV | CC | Type | Approx. | Voltage | Power |
V | A | mVrms | mArms | mV | mA | mV | mA | kg | V±10% | Approx. kVA | ||
PAD16-100LA * | 0 to 16 | 0 to 100 | 0.5 | 100 | 0.005% + 1 | 3 | 0.005% + 2 | 5 | Ⅲ | 65 | 200 | 3.3 |
PAD36-60LA * | 0 to 36 | 0 to 60 | 0.5 | 10 | 0.005% + 1 | 3 | 0.005% + 2 | 5 | Ⅲ | 66 | 200 | 3.8 |
PAD60-35LA * | 0 to 60 | 0 to 35 | 0.5 | 8 | 0.005% + 1 | 3 | 0.005% + 2 | 3 | Ⅲ | 64 | 200 | 3.4 |
PAD110-20LA * | 0 to 110 | 0 to 20 | 1 | 4 | 0.005% + 1 | 1 | 0.005% + 2 | 3 | Ⅲ | 63 | 200 | 3.8 |
PAD250-8LA * | 0 to 250 | 0 to 8 | 5 | 4 | 0.005% + 2 | 1 | 0.005% + 3 | 3 | Ⅲ | 63 | 200 | 3.4 |
* Discontinued / Limited Stock
Type Ⅳ
Open in a new windowZOOM
Specifications | Output | Ripple | Line regulation | Load regulation | Dimensions | Weight | AC input | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Model | CV | CC | CV | CC | CV | CC | CV | CC | Type | Approx. | Voltage | Power |
V | A | mVrms | mArms | mV | mA | mV | mA | kg | V±10% | Approx. kVA | ||
PAD36-100LA * | 0 to 36 | 0 to 100 | 0.5 | 50 | 0.005% + 1 | 3 | 0.005% + 2 | 5 | Ⅳ | 96 | 200 | 7.1 |
PAD60-60LA * | 0 to 60 | 0 to 60 | 0.5 | 20 | 0.005% + 1 | 3 | 0.005% + 2 | 5 | Ⅳ | 96 | 200 | 6.9 |
PAD110-32LA * | 0 to 110 | 0 to 32 | 1 | 10 | 0.005% + 1 | 3 | 0.005% + 2 | 5 | Ⅳ | 94 | 200 | 6.7 |
PAD250-15LA * | 0 to 250 | 0 to 15 | 5 | 5 | 0.005% + 2 | 1 | 0.005% + 3 | 3 | Ⅳ | 92 | 200 | 6.7 |
* Discontinued / Limited Stock
Common specifications
Open in a new windowZOOM
Item | Description | |
---|---|---|
Constant voltage temperature coefficient | 50 ppm/°C (standard value) | |
Transient response time | Time until the output voltage recovers to within when the output current changes 5 % to 100 %. 50 μs (standard value) | |
Ripple noise | 5Hz to 1MHz, ±3dB bandwidth, average value indication, measured by ground- ing plus or minus output with an rms value display AC voltage waveform | |
Meters | Voltmeter | Maximum display 4 digits |
Accuracy | ±(0.5% of reading+5 digit)*1 | |
Ammeter | Maximum display 4 digits | |
Accuracy | ±(1% of reading+5 digit)*1 | |
Ground | Plus or minus terminal can be grounded | |
Ground voltage | ±250 V DC excluding PAD110-20LA/PAD250-8LA/PAD110-32LA/PAD250- 15LA of which Isolation Voltage is ±500 V | |
Insulation resistance | Chassis-input: 500 V DC 30 MΩ min. Output-chassis: 500 V DC 20 MΩ min. | |
Withstanding voltage | No abnormalities when 1500 VAC applied for 1 minute. | |
Operating temperature range | 0 to +40°C | |
Operating humidity range | 10%rh to 90%rh | |
Cooling system | Forced air cooling using fan | |
Protection devices |
| |
Dimensions | Type Ⅲ | 430(16.93 ̋)W X 218(8.58 ̋)H X 549(21.61 ̋)Dmm(inch) |
Type Ⅳ | 430(16.93 ̋)W X 484.6(19.08 ̋)H X 465(18.31 ̋)Dmm(inch) | |
Accessories | Common specifications | Operation manual : 1 copy , Guard caps : 2 pcs , Weight sticker : 1 sheet |
Type Ⅲ | Power cord : 3-core cabtire cable for 200 VAC 1 pc. ( 3.5 mm2 , approx. 3 m ) | |
Type Ⅳ | Power cord : Single wire cable 3 pcs. ( 8 mm2 , approx. 3 m ) , Cable clamper : 1 set |
*1 At 23°C±5°C.
Dimensions(mm)
Type Ⅲ
Type Ⅳ
Options
Power Supply Controllers
Interface unit for digital control
Rack mount bracket
Type Ⅲ
<!–
タイプⅣ
–>Brank panel
*It is not necessary for installing the blank panel in case of rack mount for type IV.
Product Catalog
Variable Regulated DC Power Supply | PAD-LA Series
Operation Manuals
PAD-LA