| Item | Common to all models | ||
|---|---|---|---|
| Synchronization function (clock synchronization) | Overview | After connecting to another PXB series using the EXT SYNC connector, the SYNC icon appears on the display when synchronization is established with the internal clock. | |
| Sequence synchronization | Synchronization of the program start and step start. | ||
| Measurement synchronization | Synchronization of the measurement start | ||
| Output synchronization | Synchronization of output ON/OFF | ||
| Sequence function | Operation mode | CV mode, CC mode, CP mode | |
| Maximum number of programs | 30 | ||
| Maximum number of steps | 10000 | ||
| Step execution time | 1 ms to 3600000 s | ||
| Loop count | 1 to 100000, or infinite | ||
| Multichannel (VMCB) function | Connection between master unit and PC | LAN, USB, RS232C | |
| Connection with slave units | LAN | ||
| Sine Function | Operation mode | CV mode, CC mode | |
| Frequency setting range | 1 Hz to 1000 Hz | ||
| Frequency resolution | 1 Hz to 10 Hz | 0.2 Hz | |
| 12 Hz to 100 Hz | 2 Hz | ||
| 120 Hz to 1000 Hz | 20 Hz | ||
| CV | Maximum setting | Setting range up to 105 % of rated voltage | |
| Maximum offset setting | Setting range up to 105 % of rated voltage | ||
| CC | Maximum setting | Setting range up to 210 % of rated current | |
| Maximum offset setting | Setting range up to ±105 % of rated current | ||
| Pulse function | Operation mode | CV mode, CC mode | |
| Frequency setting range *1 | 1 Hz to 1000 Hz | ||
| Frequency resolution | 1 Hz to 10 Hz | 0.01 Hz | |
| 12 Hz to 100 Hz | 0.1 Hz | ||
| 120 Hz to 1000 Hz | 1 Hz | ||
| CV | High level rated current | Setting range up to 105 % of rated voltage | |
| Low level rated current | Setting range up to 105 % of rated voltage | ||
| CC | High level rated current | Setting range up to 105 % of rated current | |
| Low level rated current | Setting range up to 105 % of rated current | ||
| Measurement trigger | Measurement start condition (trigger source) | Conditions for starting measurement can be selected (when inputting from display, when inputting commands by remote control, when inputting signals by external control, and when operating in synchronization) | |
| Number of measurements | 1 to 65536 | ||
| Measurement delay time | Setting range | 0 s to 100 s | |
| Resolution | 0.1 ms | ||
| Measurement interval | Setting range | 0.1 ms to 3600 s | |
| Resolution | 0.1 ms | ||
| Measurement time | Setting range | 0.1 ms to 1 s | |
| Resolution | 0.1 ms | ||
| I-V Characteristic Function | Operation mode | CV mode, CC mode | |
| Number of setup items | 3 points to 100 points (linearly interpolated between points) | ||
| Preset memory | Number of memory entries | 20 | |
| Saved setting | Values in CV, CC, and CP modes, protection function values, IR values, bleeder, and output delay setting. | ||
| Setup Memory | Number of memory entries | 21 | |
| Saved setting | Output ON / OFF, voltage/current/power values, output current value for seamless operation (DC SEAM), Operation mode, etc. | ||
| key lock | Level 1 | Output on/off and preset memory recall are available | |
| Level 2 | Output on/off are available | ||
| Level 3 | Output off is available | ||
| Number of parallel operated load modules | Up to 25 units * Please consult with us if you would like to operate 10 or more units in parallel. | ||



