PMX-E (2026/05)_spec

ModelPMX18-2EPMX18-5EPMX35-1EPMX35-3EPMX70-1EPMX110-0.6E
AC input
Rated input rating100 VAC, 50 Hz / 60 Hz, single phase (117 / 200 / 217 / 234 VAC available as factory options)
Input voltage range± 10 %
Input frequency range47 Hz to 63 Hz
Inrush current (MAX)50 A60 A45 A60 A65 A55 A
Power150 VA310 VA150 VA310 VA230 VA210 VA
Output
RatingOutput voltage18.00 V18.00 V35.00 V35.00 V70.00 V110.0 V
Output current2.000 A5.000 A1.000 A3.000 A1.000 A0.600 A
Output power36 W90 W35 W105 W70 W66 W
VoltageSetting range0 V to 18.90 V0 V to 18.90 V0 V to 36.75 V0 V to 36.75 V0 V to 73.50 V0 V to 115.5 V
Setting resolution *11 mV2 mV10 mV
Setting accuracy± (0.2 % of setting + 0.1 % of rating)
Power fluctuation*2±1 mV±1 mV±3 mV±3 mV±5 mV±7 mV
Load variation*3±2 mV±5 mV±3 mV±4 mV±5 mV±7 mV
Transient response *450 μs100 μs
Ripple noise (rms) *50.5 mV (1 mV)0.5 mV0.5 mV (1 mV)0.5 mV1 mV2 mV
Rise time *6Rated load120 ms or less150 ms or less120 ms or less
No load120 ms or less150 ms or less120 ms or less
Fall time *7Rated load50 ms or less50 ms or less50 ms or less
No load120 ms or less150 ms or less120 ms or less
Max. remote sensing compensation voltage0.6 V (one‑way)
Temperature coefficient (TYP)100 ppm/℃
Current
Setting range0 A to 2.10 A0 A to 5.25 A0 A to 1.05 A0 A to 3.15 A0 A to 1.050 A0 A to 0.630 A
Setting resolution *10.1 mA
Setting accuracy± (0.3 % of setting + 0.1 % of rating)
Line regulation±5 mA±2 mA±2 mA
Load regulation±5 mA±5 mA±5 mA
Ripple noise (rms) *51 mA2 mA1 mA1 mA1 mA
Temperature coefficient (TYP)200 ppm/°C

*1 It’s possible to set a value equal to one-tenth of the smallest digit by using the SHIFT key in combination with the knob, or via communication command. *2 100 VAC~ 90 VAC, or 100 VAC~ 110 VAC, at rated load. *3 0% to 100% of the output voltage or output current. *4 The time required for the output voltage to return to within ± (0.05% + 10 mV) of the rated output voltage when the load current is varied between 10% and 100% of rated output current. *5 At rated load. Measurement frequency bandwidth: 10 Hz~ 1 MHz. *6 Time required for the output voltage to rise to between 10% and 90% of the rated output after the output is turned on. *7 The time it takes for the output voltage to drop to between 90% and 10% of the rated output when the output is turned off.