Item/Model | PBZ20-20A | PBZ20-20 | PBZ40-10 | PBZ60-6.7 | PBZ80-5 | |
---|---|---|---|---|---|---|
Overvoltage protection | Protection operation *1, *2 | OVP or V-LIMIT (output limit). Select whether output or the POWER switch turns off when OVP is activated. | ||||
Setting range (Bipolar mode) | Select whether (-110 % of rating ≤ -V.LIM ≤ +V.LIM ≤ +110 % of rating) or (-110 % of rating ≤ -OVP ≤ -1% of rating, +1 % of rating ≤ +OVP ≤ +110 % of rating) | |||||
Setting range (Unipolar mode) | Select whether (-1 % of rating ≤ -V.LIM ≤ +V.LIM ≤ +110 % of rating) or (+ 1% of rating ≤ +OVP ≤ +110 % of rating) | |||||
Setting resolution | 0.01 V | |||||
Setting accuracy | ±1 % of rating | |||||
Overcurrent protection *3 | Protection operation *1, *2 | OCP or I-LIMIT (output limit). Select whether output or the POWER switch turns off when OCP is activated. | ||||
Selectable range | Select wheter (-110 % of rating ≤ -I.LIM ≤ -1% of rating, +1 % of rating ≤ +I.LIM ≤ +110 % of rating) or (-110 % of rating ≤ -OCP ≤ -1 % of rating, +1 % of rating ≤ +OCP ≤ +110 % of rating) | |||||
Setting resolution | 0.01 A | |||||
Setting accuracy | ±1 % of rating | |||||
Overheat protection | Protective operation | Turns output off when overheating is detected. | ||||
Overheat protection Power limit (sink power) | Bipolar mode | 100 W (TYP) | 100 W (TYP) | 180 W (TYP) | 200 W (TYP) | |
Unipolar mode | 400 W (TYP) | 402 W (TYP) | 400 W (TYP) |
* 1. Voltage is detected at the output terminals. * 2. OVP is activated even when V-LIMIT (voltage limit) is selected. The OVP activation point is approximately ±120 % of rtg. * 3. Peak current at 120 Apeak can be output for 10 ms with the CC mode response set to 1 ms. For other CC mode response settings, the peak current is limited (I.LIM) according to the specified response.