SD012-PCR-LE/WE (Avionics Test Software) – Update

Update Module for SD012-PCR-LE/WE (Avionics Test Software)

This is the latest update module for SD012-PCR-LE/WE (Avionics Test Software). To install this module, your PC must already install SD012-PCR-LE/WE (Avionics Test Software).

SD012-PCR-LE SD012-PCR-WE

SD012-PCR-LE (Avionics Test Software)

Ver.

2.01

Last update

2024/5/16

Configuration

  • Applied Products: SD012-PCR-LE Ver.1.X
  • Applied Products: SD012-PCR-LE Ver.2.X
  • Windows 10 (x86/x64)
  • Windows 11 (x64)

your PC must already install SD012-PCR-LE (Avionics Test Software).

Download

Release Notes

SD012-PCR-LE
Ver 2.0.1
2023-11-20

Avionics Test Software

  • Resolved issues For data set to the H range, data with voltage below 150V has been corrected to the L range.
  • Resolved issues It has been corrected so that in DO-160 16.5.1.8 Voltage Distortion A(CF)&A(NF) and A(WF), the rms value of the waveform file will be the minimum value.
  • Resolved issues Fixed a bug that the repeat count was too many by one for all standard tests.
Ver 2.0.0
2022-4-22

Avionics Test Software

  • New Feature Added waveform preview screen to main screen and step list.
  • New Feature Added "Add" and "Delete" buttons for steps to the step list.
  • New Feature Added "Wave" button for steps to the step list, and added a function to create and edit arbitrary waveforms.
  • New Feature Added "Output OFF" button to the step list.
  • New Feature Added message box display when output is ON.
Ver 1.1.1
2021-4-7

Avionics Test Software

  • Improvement Revised the operation guide.
Ver 1.1.0
2020-11-17

Avionics Test Software

  • New Feature Added the display of the currently set "output mode" to the main screen.
  • New Feature Added "Show message box" to the options.
  • Resolved issues Fixed a bug that the previous test conditions were not reflected when the application was restarted immediately after loading the User file.
Ver 1.0.5
2020-03-12

Avionics Test Software

  • Resolved issues Added in DO-160F,G 16.5.1.2 because the number of test levels was small.
  • Resolved issues In DO-160F,G 16.5.1.3, the test step frequency was half of the standard value, so there was an error in the number of corrections and repetitions.
  • Resolved issues There was an error in the repetition of DO-160F, G standard test data.
  • Resolved issues In DO-160F,G 16.5.2.3.2, there was an error in the interval time.
  • Resolved issues In DO-160F,G 16.5.1.8, the arbitrary waveforms of A (WF) and A (CF) / A (NF) were the same.
  • Resolved issues In DO-160G 16.6.1.3b, Table16-3 has changed.
  • Resolved issues In DO-160F,G 16.6.1.3c, 16.6.1.3d, 16.5.1.4b, c, d, the interval time was corrected to 10 seconds.
  • Resolved issues In DO-160F,G 16.6.1.3d, the setting voltage range was incorrect.
  • Resolved issues In DO-160G 16.5.1.4, 16.5.1.4b, 16.5.1.4c, the setting voltage range was incorrect.
  • Resolved issues In DO-160F 16.5.1.4c, the setting voltage range was incorrect.
Ver 1.0.4
2019-3-12

Avionics Test Software

  • New Feature In this version, test conditions were subdivided for each TestNo.
Ver 1.0.3
2015-4-21

Avionics Test Software

  • Resolved issues List of Errors pages were added to Operation Guide.
Ver 1.0.2
2014-7-1

Avionics Test Software

  • New Feature In this version, I added function for being able to select all listed tests.
  • Resolved issues A Voltage range setting of MIL-STD-704 LDC test data had a problem.
Ver 1.0.1
2014-1-9

Avionics Test Software

  • Resolved issues A Loop setting of MIL-STD-704E and F test data had a problem.
  • Resolved issues An unnecessary test was included in MIL-STD-704E.
  • Resolved issues A Loop setting of DO-160F and G test data had a problem.
  • Resolved issues A Loop setting of JIS W0812 test data had a problem.
Ver 1.0.0
2013-8-7

Avionics Test Software

  • New Feature The first release.

SD012-PCR-WE (Avionics Test Software)

Ver.

2.01

Last update

2024/5/16

Configuration

  • Applied Products: SD012-PCR-WE Ver.1.X
  • Applied Products: SD012-PCR-WE Ver.2.X
  • Windows 10 (x86/x64)
  • Windows 11 (x64)

your PC must already install SD012-PCR-WE (Avionics Test Software).

Download

Release Notes

SD012-PCR-WE
Ver 2.0.1
2023-11-20

Avionics Test Software

  • Resolved issues For data set to the H range, data with voltage below 160V has been corrected to the L range.
  • Resolved issues It has been corrected so that in DO-160 16.5.1.8 Voltage Distortion A(CF)&A(NF) and A(WF), the rms value of the waveform file will be the minimum value.
  • Resolved issues Fixed a bug that the repeat count was too many by one for all standard tests.
Ver 2.0.0
2022-4-22

Avionics Test Software

  • New Feature Added waveform preview screen to main screen and step list.
  • New Feature Added "Add" and "Delete" buttons for steps to the step list.
  • New Feature Added "Wave" button for steps to the step list, and added a function to create and edit arbitrary waveforms.
  • New Feature Added "Output OFF" button to the step list.
  • New Feature Added message box display when output is ON.
  • New Feature Added control of 8kVA single-phase/three-phase output trans "OT03-PCR-WEA".
  • New Feature Added voltage correction function.
Ver 1.2.0
2021-4-7

Avionics Test Software

  • New Feature Compatible with PCR-WEA series.
Ver 1.1.0
2020-12-17

Avionics Test Software

  • New Feature Added the function of "Setting the Wiring Method of the AC Power Supply".
  • New Feature Added the display of the currently set "output mode" to the main screen.
  • New Feature Added "Show message box" to the options.
  • Resolved issues Fixed a bug that the previous test conditions were not reflected when the application was restarted immediately after loading the User file.
Ver 1.0.0
2020-3-12

Avionics Test Software

  • New Feature The first release.