Item/Model | PBZ20-20A | PBZ20-20 | PBZ40-10 | PBZ60-6.7 | PBZ80-5 | |
---|---|---|---|---|---|---|
Environmental conditions | Operating environment | Indoor use, overvoltage category II | ||||
Operating temperature and humidity range | 0 °C to +40 °C (+32 °F to +104 °F) / 20 %rh to 85 %rh (no condensation) | |||||
Storage temperature and humidity range | -25 °C to +70 °C (-13 °F to +158 °F) / 90 %rh or less (no condensation) | |||||
Grounding polarity | Only the output’s COM terminal can be grounded. | |||||
Isolation voltage | 500 Vdc max | |||||
Withstanding voltage | Across the primary circuit and chassis | No abnormalities at 1500 Vac for 1 minute | ||||
Across the primary circuit and the output terminals | ||||||
Insulation resistance | Across the primary circuit and chassis | 500 Vdc, 30 MΩ or greater (at 70 %rh humidity or less) | ||||
Across the primary circuit and the output terminals | ||||||
Across the output terminals and chassis | 500 Vdc, 1 MΩ or greater (at 70 %rh humidity or less) | |||||
Earth continuity | Power cord inlet, across the earth pin and chassis | 25 Aac, 0.1 Ω or less | ||||
Cooling method | Forced air cooling using a heat sensing variable speed fan. | |||||
Safety*1 | Conforms to the requirements of the directive and standard below. Low Voltage Directive 2014/35/EU *2 EN 61010-1 (Class I *3 , Pollution degree 2 *4 ) | |||||
Electromagnetic compatibility (EMC)*1*2 | Conforms to the requirements of the directive and standard below. EMC Directive 2014/30/EU EN 61326-1 (Class A *5), EN 55011 (Class A *5, Group 1 *6), EN 61000-3-2, EN 61000-3-3 Applicable condition All of the cables and wires connected to the PBZ are less than 3 m in length. | |||||
External dimensions (largest part) | 429.5 (16.91”) W × 128 (5.0”) (145 (5.7”)) H × 550 (21.65”) (595(23.4”)) D mm | |||||
Weight | Approx. 22 kg (48.50 lb; just the PBZ) | |||||
Accessories | Power cord: 1 pc. J1 connector (Socket: 1 pc., Protective covers: 2 pairs, Terminals: 30 pc.) Heavy object warning label: 1 pc. CD-ROM: 1 pc. Operation manual (Setup guide 1 pc., Quick reference English 1pc., Japanese 1pc. Safety information 1pc.) |
* 1. Does not apply to specially made or modified PBZs. * 2. Only on models that have CE/UKCA marking on the panel. * 3. This is a Class I equipment. Be sure to ground this product’s protective conductor terminal. The safety of this product is only guaranteed when the product is properly grounded. * 4. Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary conductivity caused by condensation. * 5. This is a Class A equipment. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts. * 6. This is a Group I equipment. This product does not generate and/or use intentionally radio-frequency energy, in the form of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose.