AC VOLT METER AVM13 AVM15 AVM23 AVM25 AVM23R AVM25R

AC VOLT METER 1834A 1854C

AC VOLT METER 1651B

AC VOLT METER 1631B


SD025-PMX (Wavy for PMX) – Free Edition
Wavy for PMX Free Edition Wavy for PMX is sequence creation software that supports the PMX-A series DC power supplies. You can use Wavy for PMX to create …

Home Appliances & Consumer Electronics Evaluation
Home Appliances & Consumer Electronics Evaluation Power Supplies for Simulating Various Power Line Abnormalities Power supplies for evaluating single-phase and three-phase input devices can simulate power line abnormalities …

Rechargeable Battery Evaluation
Rechargeable Battery Evaluation Sustainable Manufacturing Processes of Rechargeable Batteries Material Evaluation Lithium-ion batteries used in next-generation vehicles, especially electric vehicles, require various evaluation tests to ensure their safety. …




AC VOLTMETER 1854A





PFX2500_Comparison of PFX2500 series specifications
Item PFX2512 PFX2532 Rating 60 V / 50 A 60 V / 200 A Communication interface LAN LAN Monitoring data minimum time interval 0.1 s 0.1 s High …

What type of test leads should I use for TOS5200?
Our test leads use high-voltage wires rated for 40 kV, AWG22, with an outer diameter of approximately 4.2 mm. Wires compliant with UL3239 standards are also considered suitable.

Model PLZ70UA PLZ150U Rating Operating voltage V 0 to 150 1.5 to 150 Current/Power Range H 15A / 75W 30A / 150W Range M 1.5A / 75W 3A …

PLZ-U_High precision and high resolution
Measurement display resolution Resolution Voltmeter 15.75V to 150V 0.01V 0 V to 15.75 V 0.001V Ammeter H 0.001A M 0.0001A L 0.01mA Wattmeter Less than 100 W …

Elapsed time The load turns off when the elapsed time value reaches the specified value. Voltage drop* The load turns off when the voltmeter value reaches the specified …

TOS9311_Insulation Resistance Test Section
Output Output voltage range -25 V to -1000 V/+0.05 kV to +10.000 kV Resolution 1 V Setting accuracy ±(1.2 % of setting + 2 V)/ ±(1.2 % …

Model PMX32-3DU PMX32-3TR PMX32-2QU Applicable channels Master: CH2, slave: CH1 Constant voltage Operating range 0 V to 64 V Selectable range 0 V to 67.2 V Setting accuracy …

Compatible International Standard ISO7637-3.2007(Second Edition) Characteristic impedance 50 Ω± 10% Coupling capacitance 200pF or smaller Maximum input voltage ± 300V Diameter that can be clamped φ 40 mm …

TOS5200_Comparison with the Kikusui previous model
Specification comparison item TOS5200 TOS5050A Appearance Test voltage Output method PWM switching amp system Slide transformer method Distortion 3 % or less As per commercial power supply waveform …