Compact, wide-range DC power supply

PWR-01 Series – 2000W model

PWR-01-2000W

425,000467,000

  • Sequence function (supports triggered synchronization)
  • Variable internal resistance function
  • LAN (LXI compliant) /USB/RS232C as standard interface
  • A virtual multi-channel bus (VMCB) function makes multi-channel operation more efficient
  • A wide range of voltage and current settings can be combined within its output power rating (3 to 4 times)
  • Supporting universal input voltage (85 V to 265 V)
  • CONFIG setting shortcut function and display (Up to three parameters can be registered.)
  • Setting preset memory function (3 combinations of settings for voltage, current, OVP, OCP, and UVL)
  • Bleeder (sink) can be turned ON/OFF, with an even stronger bleeder mode setting available
  • Output ON/OFF delay function
  • Soft start/stop function
  • Durable Performance Operating temperature guaranteed up to 50 °C (122 °F). (Storage temperature is -25 °C to +60 °C (-13 °F to 140 °F).)

LAN LXI LAN LXI UKCA
ImageSKUOutput CV [V]Output CC [A]Output Power [W]標準価格WEBかんたんお見積り
PWR2001LPWR2001L0 to 40V0 to 200A2000W425,000
(税込:467,500
PWR2001MLPWR2001ML0 to 80V0 to 100A2000W440,000
(税込:484,000
PWR2001MHPWR2001MH0 to 240V0 to 25A2000W457,000
(税込:502,700
PWR2001HPWR2001H0 to 650V0 to 9.25A2000W467,000
(税込:513,700
SKU: PWR-01-2000W

Line-up

ImageSKUOutput CV [V]Output CC [A]Output Power [W]標準価格WEBかんたんお見積り
PWR2001LPWR2001L0 to 40V0 to 200A2000W425,000
(税込:467,500
PWR2001MLPWR2001ML0 to 80V0 to 100A2000W440,000
(税込:484,000
PWR2001MHPWR2001MH0 to 240V0 to 25A2000W457,000
(税込:502,700
PWR2001HPWR2001H0 to 650V0 to 9.25A2000W467,000
(税込:513,700

Specifications

2000W model

AC input

ZOOM
Item/Model PWR2001L PWR2001ML PWR2001MH PWR2001H
Nominal input rating 100 Vac to 240 Vac, 50 Hz to 60 Hz, single phase
Input voltage range 85 Vac to 265 Vac
Input frequency range 47 Hz to 63 Hz
Current (TYP) *1 100 Vac 28.0 A
200 Vac 14.0 A
Inrush current 125 A or less
Power (MAX) *2 2800 VA
Power factor (TYP) *1 0.99 (input voltage: 100 V), 0.97 (input voltage: 200 V)
Efficiency (TYP) *1 75 %
Output hold time *2 20 ms or more

*1. At the rated output power for the rated output current. *2. 100 Vac, at the rated output power.


Output

ZOOM
Item/Model PWR2001L PWR2001ML PWR2001MH PWR2001H
Rating Output voltage *1 40 V 80 V 240 V 650 V
Output current *1 200 A 100 A 25.0 A 9.25 A
Output power 2000 W
Voltage Maximum settable voltage *2 42 V 84 V 252 V 682.5 V
Accuracy of setting ±(0.05 % of setting +0.05 % of rating)
Resolution 200 mV 400 mV 1000 mV 2500 mV
Using FINE, OUT OFF 10 mV 10 mV 100 mV 100 mV
Using FINE, OUT ON 1 mV 1 mV 10 mV 10 mV
When using a communication interface 0.1 mV 0.1 mV 0.1 mV 0.1 mV
Line regulation *3 ± 6 mV ± 10 mV ± 26 mV ± 67 mV
Load regulation *4 ± 6 mV ± 10 mV ± 26 mV ± 67 mV
Transient response *5 1 ms or less 2 ms or less 2 ms or less 3 ms or less
Ripple noise *6 p-p *7 50 mV 70 mV 120 mV 350 mV
rms *8 5 mV 5 mV 20 mV 50 mV
Rise time At full load 50 ms or less 100 ms or less
No load 50 ms or less 100 ms or less
Fall time *9 At full load 50 ms or less 150 ms 250 ms
No load 500 ms or less 1200 ms 2000 ms
Maximum remote sensing compen- sation voltage (single line) 1.5 V 4 V 5 V 5 V
Temperature coefficient *10 100 ppm/ ℃
Current Maximum settable current *2 210 A 105 A 26.25 A 9.7125 A
Setting accuracy *11 ±(0.5 % of setting +0.1 % of rating)
Resolution 1000 mA 500 mA 100 mA 50 mA
Using FINE, OUT OFF 100 mA 100 mA 10 mA 10 mA
Using FINE, OUT ON 10 mA 10 mA 1 mA 1 mA
When using a communication interface 0.1 mA 0.1 mA 0.1 mA 0.1 mA
Line regulation ± 22 mA ± 12 mA ± 4.5 mA ± 2.9 mA
Load regulation ± 45 mA ± 25 mA ± 10.0 mA ± 6.9 mA
Ripple noise *12 rms *8 400 mA 200 mA 60 mA 30 mA
Rise time (TYP) At full load 50 ms 100 ms
Fall time (TYP) At full load 50 ms 100 ms
Temperature coefficient *10 100 ppm/ ℃
Maximum internal resistance that can be set 0.200 Ω 0.8 7.200 Ω 52.70 Ω

*1. The maximum output voltage and maximum output current are limited by the maximum output power. *2. Can be limited to approximately 95 % of the OVP trip point or OCP trip point. *3. 85 Vac to 135 Vac or 170 Vac to 265 Vac, fixed load *4. The amount of change that occurs when the load is changed from no load to full load (rated output power/rated output voltage) with rated output voltage. The value is measured at the sensing point. *5. The amount of time required for the output voltage to return to a value within “rated output voltage ± (0.1 % +10 mV).” The load current fluctuation is 50 % to 100 % of the maximum current with the set output voltage. *6. Measured using an RC-9131C probe that conforms to the JEITA specifications. At the rated output current. *7. When the measurement frequency bandwidth is 10 Hz to 20 MHz. *8. When the measurement frequency bandwidth is 10 Hz to 1 MHz. *9. When the bleeder circuit is set to bleeder normal. *10. When the ambient temperature is within 0°C and 50 °C *11. Applies to the range of 1 % to 100 % of the rated current. TYP (0.1 % of rating) for 0 % to 1 %. *12. When the output voltage is 10 % to 100 % of the rating. At the rated output current.


Display function

ZOOM
Item/Model PWR2001L PWR2001ML PWR2001MH PWR2001H
Voltage display Maximum display 99.99 999.9
Display accuracy ± (0.2 % of reading +5 digits)
Current display Maximum display 999.9 99.99
Display accuracy ± (0.5 % of reading +8 digits)
Power display The PWR DSPL LED lights in red.
Maximum display 9999
Display accuracy Displays the result of multiplying the current and voltage. The display is toggled with the voltage or current display.

Unless specified otherwise, the specifications are for the following settings and conditions.
Loads are pure resistive loads. ●The product is warmed up for at least 30 minutes (with current flowing). ●After warm-up, the product must be calibrated correctly in a 23 °C ± 5 °C environment according to the appropriate calibration procedure. ●Values indicated by “TYP” are typical values. They are not guaranteed performance values. ●Values indicated by “rating” are ratings. ●Values indicated by “reading” are readings. ●Values indicated by “f.s.” are full scale values. ●The PWR-01 operates over a wide range of output voltage and output current within rated output power. However, the current that can be output with rated output voltage and the voltage that can be output with rated output current are limited by the rated output power. ●The current that can be output with rated output voltage and the voltage that can be output with rated output current are as follows. Maximum output current with rated output voltage = Rated output power/ rated output voltage. Maximum output voltage with rated output current = Rated output power/ rated output current. ●Rated load and no load are defined as follows:In constant-voltage mode (when the output current is set to a value greater than or equal to the maximum output current with rated output voltage) Rated load: Refers to a resistive load that, when the rated output voltage is applied,makes the flowing current 95 % to 100 % of the maximum output current with rated output voltage.No load:Refers to a load through which no output current flows. In other words,refers to an open load (no load being connected). In constant-current mode (when the output voltage is set to a value greater than or equal to the maximum output voltage with rated output current) Rated load:Refers to a resistive load that, when the rated output current flows, makes the voltage drop to 95 % to 100 % of the maximum output voltage with rated output current. Including the voltage drop in the load cables, the PWR-01 output voltage must not exceed the maximum output voltage with rated output current. No load:Refers to a resistive load that, when the rated output current flows, makes the voltage drop to 10 % of the maximum output voltage with rated output current or 1 V whichever is higher. ●The specifications of the PWR-01 apply to the rear-panel output terminals.

Common specifications

Protection functions

ZOOM
Item/Model 400W 800W 1200W 2000W
Overvoltage protection (OVP) Turns the output off *1, displays OVP, and lights ALM
Selectable range 10 % to 112 % of the rated output voltage
Setting accuracy ±(1.5 % of rating)
Overcurrent protection (OCP) *2 Turns the output off *1, displays OCP, and lights ALM
Selectable range 10 % to 112 % of the rated output voltage
Setting accuracy ±(3 % of rating)
Front-panel output terminal overcurrent protection (FOCP)*3 Turns the output off *1, displays FOCP, and lights ALM
Value (fixed) 11 A (TYP)
Undervoltage limit (UVL) Cannot be set to a value less than or equal to the set voltage
Selectable range 0 % to 105 % of the rated output voltage
Overheat protection (OHP) Turns the output off, displays OHP, and lights ALM
Incorrect sensing connection protection (SENSE) Turns the output off, displays SENS, and lights ALM
Low AC input protection (AC-FAIL) Turns the output off *4, displays AC, and lights ALM
Shutdown (SD) Turns the output off *1, displays SD, and lights ALM
Power limit (POWER LIMIT) ALM blinking
Value (fixed) Approx. 105% of the rated output power
Communication monitoring (watchdog) Turns the output off, displays WDOG, and lights ALM
Master-slave parallel operation protection (PRL ALM) Turns the output off *1, displays PRL, and lights ALM

*1. Output off or breaker trip on the 2000 W model. *2. This does not protect against the discharge current peak that is generated from the capacitors inside the PWR-01 output section when the load is changed suddenly. *3. Available on models with a maximum settable current of 11 A or more. If the OCP value is less than the FOCP value, the OCP value takes precedence. *4. Auto recovery after eliminating the cause of the alarm is selectable.


Signal output and input

ZOOM
Item/Model 400W 800W 1200W 2000W
Monitor signal output Voltage monitor (VMON) Selectable monitor voltage range: 0 V to 5 V or 0 V to 10 V
Setting accuracy 2.5 % of f.s. *1
Current monitor (IMON) Selectable monitor voltage range: 0 V to 5 V or 0 V to 10 V
Setting accuracy 2.5 % of f.s. *1
Status signal output *2 OUTON STATUS On when output is on.
CV STATUS Turns on during CV operation
CC STATUS Turns on during CC operation
ALARM STATUS Turns on when an alarm has been activated
POWER ON STATUS Turns on when the power is turned on
Trigger signal Input (TRG IN) Logic selectable: LOW (0 V to 1.5 V), HIGH (3.5 V to 5 V)
Input impedance: 10 kΩ (TYP)
Output (TRG OUT) Logic selectable: LOW (0 V to 0.6 V), HIGH (4.2 V to 5 V)
Pulse width: 100 μs (TYP)

*1. f.s. is the full scale at the selected range. It is 10 V for the 10 V range and 5 V for the 5 V range. *2. Photocoupler open collector output; maximum voltage 30 V, maximum current (sink) 8 mA; isolated from the output and control circuits; status commons are floating (withstand voltage of less than or equal to 60 V); and status signals are not mutually isolated.


Control functions

ZOOM
Item/Model 400W 800W 1200W 2000W
External control Output voltage control (VPGM) 0 % to 100 % of the rated output voltage
Selectable control voltage range: 0 V to 5 V or 0 V to 10 V
Accuracy 5 % of rating
Output current control (IPGM) 0 % to 100 % of the rated output current
Selectable control voltage range: 0 V to 5 V or 0 V to 10 V
Accuracy 5 % of rating
Output on/ off control OUTPUT ON/OFF CONT Logic selectable: Output on when set to LOW (0 V to 0.5 V) or shorted; output off when set to HIGH (4.5 V or 5 V) or open Output on when set to HIGH (4.5 V to 5 V) or open; output off when set to LOW (0 V or 0.5 V) or shorted
Output shutdown control SHUT DOWN Output on when set to LOW (0 V to 0.5 V) or shorted
Alarm clear control ALM CLR Alarm cleared when set to LOW (0 V to 0.5 V) or shorted

Other functions

ZOOM
Item/Model 400W 800W 1200W 2000W
Output-on/ off delay Setting range: 0.0 s, 0.5 s to 99.9 s *1 setting resolution: 0.1 s
Soft start and soft stop Setting range: 0.0 s, 0.5 s to 10.0 s *1 setting resolution: 0.1 s
Overcurrent protection (OCP) activation delay Setting range: 0.0 s to 2.0 s *1 setting resolution: 0.1 s
Preset memory Up to three sets of the following settings can be saved: the set voltage, the set current, the set OVP, the set OCP, and the set UVL.
key lock Locks the operation of all keys other than the OUTPUT key.
CONFIG shortcut Up to three CONFIG parameters can be registered to the SC1, SC2, and SC3 keys
Sequence Number of programs: 1
Number of steps: 64
Repetition count: 1 to 99998, INFinity
Number of configurable interval loops: 16
Number of interval loops: 2 to 99998
Step time: 0.1 s to 100 h
(common to step transition and ramp transition)
Synchronized Operation Synchronization of voltage and current settings, synchronization of the resumption of steps in a sequence program
Master-slave parallel operation *2 Up to three units (same models) including the master unit Up to two units (same models) including the master unit
Series operation *3 Two units (the same model)
Multichannel (VMCB) Connection between the master unit and PC LAN, USB, RS232C
Connection with slave units LAN

*1. Factory default is 0.0 s. *2. Current difference between the master and slaves is 5 % (TYP). *3. H type is excluded


Operation display

ZOOM
Item/Model 400W 800W 1200W 2000W
OUTPUT ON/OFF OUTPUT LED lights green when the output is on.
Output-on/ off delay “DLY” lights when it is set and blinks when it is in effect.
OUTPUT LED blinks orange while outputon delay is in effect.
OUTPUT LED blinks green while output-off delay is in effect.
Soft start and soft stop “SS” lights when it is set and blinks when it is in effect.
OUTPUT LED lights green when soft start is in effect.
OUTPUT LED blinks green when soft stop is in effect.
CV operation CV LED lights in green.
CC operation CC LED lights in red.
Alarm operation ALM LED lights in red when a protection function has been activated.
ALM LED blinks red when the power limit (POWER LIMIT) is activated.
OUTPUT LED blinks orange when a protection function is activated when the output is on.
Preset memory PRESET A, B, or C LED lights green when a preset memory entry is being recalled or saved.
Key lock operation LOCK LED lights green when the keys are locked.
Remote operation REMOTE LED lights green during remote control.
LAN operation

LAN LED lights or blinks depending on the status.

  • No fault status: Lights green.
  • Fault status: red.
  • Standby status: Lights orange.
  • WEB identify status: Blinks green.
Bleeder circuit “HB” lights when the hyper bleeder is set.
Variable internal resistance (VIR) “VIR” lights when it is set.
Sequence “SEQ” lights when a sequence is being executed and blinks the PWR-01 is waiting for a trigger.

Interface

ZOOM
Item/Model 400W 800W 1200W 2000W
Common specifications Software protocol IEEE Std 488.2-1992
Command language Complies with SCPI Specification 1999.0
RS232C Hardware Complies with the EIA232D specifications (excluding the connector)
RJ-45 connector (male) *1
Baud rate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Data length: 8 bits, Stop bits: 1 bit, Parity bit: None
No flow control
Program message terminator LF during reception, CR/LF during transmission
USB Hardware Complies with the USB 2.0 specifications; data rate: 480 Mbps (HighSpeed)
Socket B type
Program message terminator LF or EOM during reception, LF + EOM during transmission
Device class Complies with the USBTMC-USB488 device class specifications
LAN Hardware IEEE 802.3 100Base-TX/10Base-T Ethernet
Complies with LXI Specification2011 Ver.1.4
Complies with LXI HiSLIP Extended Function Rev.1.01
IPv4, RJ-45 connector *2
Communication protocol VXI-11, SCPI-RAW, HiSLIP
Program message terminator VXI-11, HiSLIP: LF or END during reception, LF + END during transmission SCPI-RAW: LF during reception, LF during transmission.

*1. The RD-8P/9P adapter cable is an option. *2. Category 5; use a straight cable.


General

ZOOM
Item/Model 400W 800W 1200W 2000W
Weight (main unit only) Approx. 3 kg (6.61 lb) Approx. 5.5 kg (12.13 lb) Approx. 7.5 kg (16.53 lb) Approx. 13 kg (28.66 lb)
Dimensions See the outline drawing.(Catalogue p15)
Environmental conditions Operating environment Indoor use, overvoltage category II
Operating temperature 0 °C to +50 °C (32 °F to +122 °F)
Operating humidity 20 %rh to 85 %rh (no condensation)
Storage temperature -25 °C to +60 °C (-13 °F to 140 °F)
Storage humidity 90 %rh or less (no condensation)
Altitude Up to 2000 m
Cooling method Forced air cooling using fan
Grounding polarity Negative grounding or positive grounding possible
Isolation voltage L/ ML/ MH type: ±500 Vmax H type: ±800 Vmax
Withstanding voltage Across the primary circuit and chassis No abnormalities when 1500 Vac is applied for 1 minute
Across the primary and secondary circuits L/ ML/ MH type: No abnormalities when 1650 Vac is applied for 1 minute
H type: No abnormalities when 1900 Vac is applied for 1 minute
Across the secondary circuit and chassis L/ ML/MH type: No abnormalities when 2300 Vdc is applied for 1 minute
H type: No abnormalities when 2640 Vdc is applied for 1 minute
Insulation resistance Across the primary circuit and chassis 100 MΩ or more (70 %rh or less) at 500 Vdc
Across the primary and secondary circuits LL/ ML/ MH type: 100 MΩ or more (70 %rh or less) at 500 Vdc
H type: 100 MΩ or more (70 %rh or less) at 1000 Vdc
Across the secondary circuit and chassis L/ ML/ MH type: 40 MΩ or more (70 %rh or less) at 500 Vdc
H type: 40 MΩ or more (70 %rh or less) at 1000 Vdc
Accessories
  • Operation Manuals
  • Chassis connection short bar
  • Output terminal M4 screws (2 pcs.)
  • Output terminal cover
  • Output terminal bolt set (2 sets) M8 bolt set (For 400 W, 800 W and 1200 W model)
  • M10 bolt set (For 2000 W model) *Only L type and ML type included.
  • Power cord *Included only with the 400 W/800 W model
  • Input terminal cover *Included only with the 1200 W model
  • Ferrite core set *Included only with the 1200 W model
Electromagnetic compatibility *1 *2

Complies with the requirements of the following directive and standard.

  • EMC Directive 2014/30/EU
  • EN61326-1 (Class A *3),
  • EN 55011 (Class A *3, Group 1 *4),
  • EN 61000-3-2 EN 61000-3-3

Applicable under the following conditions:
The maximum length of all cabling and wiring connected to the product must be less than 3 m.

Safety *1 Complies with the requirements of the following directive and standard. Low Voltage Directive 2014/35/EU *2 EN 61010-1 (Class I *5 , Pollution Degree 2 *6)

*1. Does not apply to specially ordered or modified products. *2. Limited to products that have a CE mark. Does not apply unless a core is attached to the J1 connector cable. *3. This is a Class A instrument. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts. *4. This is a Group 1 instrument. This product does not generate and/or use intentionally radiofrequency energy, in the form of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose. *5. This is a Class I instrument. Be sure to ground this product’s protective conductor terminal. The safety of this product is guaranteed only when the product is properly grounded. *6. Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only nonconductive pollution will occur except for an occasional temporary conductivity caused by condensation.


Product Catalog

Operation Manuals

PWR-01
Icon

    2D CAD

    Base view | DXF 278.20 KB
    Icon
    Base view | PDF 252.96 KB
    Icon
    Outline | DXF 532.02 KB
    Icon
    Outline | PDF 117.95 KB
    Icon

      Technical Data

      PWR-01 Series - Characteristics Data
      Icon

        Please feel free to contact us with any questions or concerns.

        Download a Product Catalog View List
        Request a Quotation Contact Us
        close

        Search