High-performance multifunctional AC Power Supplies
PCR-LE2 Series
PCR-LE2-SERIES
3,700,000円 – 14,000,000円
- High-quality/high-stability output with a high-speed linear amp
- Capable of various power line abnormality simulations and sequence operation
- Single-phase 500 VA to 9 kVA, supporting the system for the single-phase, and expandable with optional drivers for the single-phase three-wire, and three-phase operation
- Expandable capacity up to 27 kVA (single-phase), 54 kVA (single-phase three-wires), and 81 kVA (three-phase)
- Equipped with various measuring functions
- Features a full range of measuring functions and supports AC, DC, and AC + DC Outputs
- Detachable front panel
- Eco-friendly function equipped
For PCR12000LE2, PCR18000LE2, and PCR27000LE2, installation costs are required separately.
Line-up
Model | Output capacity | Maximum output current | AC mode (L/H range) | DC mode (L/H range) | Price | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Single-phase, Three phase 4-wire | Single phase 3-wire | Single phase | Single phase 3-wire | Single phase | Three phase 4-wire | Single phase | Single phase 3-wire | ||||
PCR6000LE2 | 6kVA | 4kVA | 60A/30A | 20A/10A | 1 V to 150 V / 2 V to 300 V | 60A/30A | 20A/10A | ±1.4 V to ±212 V / ±2.8 V to ±424 V | 42A/21A | 14A/7A | 3,700,000円 (税込:4,070,000円) |
PCR9000LE2 | 9kVA | 6kVA | 90A/45A | 30A/15A | 90A/45A | 30A/15A | 63A/31.5A | 21A/10.5A | 5,800,000円 (税込:6,380,000円) | ||
PCR12000LE2 | 12kVA | 8kVA | 120A/60A | 40A/20A | 120A/60A | 40A/20A | 84A/42A | 28A/14A | 6,980,000円 (税込:7,678,000円) | ||
PCR18000LE2 | 18kVA | 12kVA | 180A/90A | 60A/30A | 180A/90A | 60A/30A | 126A/63A | 42A/21A | 10,000,000円 (税込:11,000,000円) | ||
PCR27000LE2 | 27kVA | 18kVA | 270A/135A | 90A/45A | 270A/135A | 90A/45A | 189A/94.5A | 63A/31.5A | 14,000,000円 (税込:15,400,000円) |
Specifications
Input ratings (AC rms)
Item/Model | PCR6000LE2 | PCR9000LE2 | PCR12000LE2 | PCR18000LE2 | PCR27000LE2 | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | ||
Voltage | Line voltage 170 V to 250 V | Line voltage 324 V to 440 V (Phase voltage 187 V to 254 V) | Line voltage 170 V to 250 V | Line voltage 324 V to 440 V (Phase voltage 187 V to 254 V) | Line voltage 170 V to 250 V | Line voltage 324 V to 440 V (Phase voltage 187 V to 254 V) | Line voltage 170 V to 250 V | Line voltage 324 V to 440 V (Phase voltage 187 V to 254 V) | Line voltage 170 V to 250 V | Line voltage 324 V to 440 V (Phase voltage 187 V to 254 V) | |
Phase | Single phase | Three phase 3-wire | Three phase 4-wire | Three phase 3-wire | Three phase 4-wire | Three phase 3-wire | Three phase 4-wire | Three phase 3-wire | Three phase 4-wire | Three phase 3-wire | Three phase 4-wire |
Frequency | 47 Hz to 63 Hz | ||||||||||
Apparent power | Approx. 10.6 kVA | Approx. 15.7 kVA | Approx. 23 kVA | Approx. 33 kVA | Approx. 48 kVA | ||||||
Power factor *1 | 0.97 (TYP) | ||||||||||
Max. current | 64 A or less | 38A or less | 21A or less | 55A or less | 30A or less | 75A or less | 39A or less | 111A or less | 59A or less | 165A or less | 91A or less |
*1 When the output phase voltage is 100 V or 200 V, the output current is the rated value, the load power factor is 1, and the output frequency is between 40 Hz and 999.9 Hz.
AC mode output ratings (AC rms)
Item/Model | PCR6000LE2 | PCR9000LE2 | PCR12000LE2 | PCR18000LE2 | PCR27000LE2 | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | ||
Phase voltage (output L range, output H range)*2 | 1 V to 150 V / 2 V to 300 V | ||||||||||
Voltage setting range | 0 V to 152.5 V / 0 V to 305.0 V | ||||||||||
Voltage setting accuracy (output L range, output H range)*3 | ±(0.3 % of set + 0.6 V) | ||||||||||
Max. current*4 | Single phase, poly phase, L range, H range | 60 A, 30 A · 20 A, 10 A | 90 A, 45 A · 30 A, 15 A | 120 A, 60 A · 40 A, 20 A | 180 A, 90 A · 60 A, 30 A | 270 A, 135 A · 90 A, 45 A | |||||
Phase*5 | Single phase · Single phase3-wire · Three phase 4-wire | ||||||||||
Power capacity | Single phase, Three-phase 4-wire, Single phase 3-wire | 6 kVA · 4 kVA | 9 kVA · 6 kVA | 12 kVA · 8 kVA | 18 kVA · 12 kVA | 27 kVA · 18 kVA | |||||
Maximum peak current*6 | Max. current (rms) × 4 (TYP) | ||||||||||
Max. reverse current*7 | 30 % of the max. current (rms) | ||||||||||
Load power factor*4 | 0 to 1 (leading or lagging) | ||||||||||
Frequency*4 *8 *9 | 1 Hz to 999.9 Hz ★ |
*2 L/H range can be changed by means of a switch on the front panel. Resolution: 0.1V
*3 出When the output frequency is between 45 Hz and 65 Hz, with no load, and at room temperature. *4 When the maximum voltage is between 1 V and 100 V (L range) or 2 V and 200 V (H range) and the load power factor is between 0.8 and 1.When the output phase voltage is between 100 V and 150 V or 200 V and 300 V (AC mode) or ±100 V and ±212 V or ±200 V and ±424 V (DC mode), the output current is reduced by the output phase voltage.
When the load power factor is between 0 and 0.8, the output current is reduced by the load power factor. (AC mode) When the output frequency is between 1 Hz and 40 Hz, the output current is reduced by the output frequency. (AC mode) *5 The output phase mode can be changed by means of a key on the operation panel. “Poly” in the table indicates single- phase three-wire mode and three-phase four-wire mode. *6 When the output phase voltage is in the vicinity of the peak (±15 deg) (However, this is limited by the rated output current’s rms value). *7 When the output phase voltage is 100 V or 200 V and the output frequency is between 40 Hz and 999.9 Hz (reverse current is −90 deg to −180 deg / 90 deg to 180 deg out of phase with the output voltage).
*8 Resolution : 0.01Hz (1.00 Hz to 100.0 Hz), 0.1Hz(100.0 Hz to 999.9 Hz) *9 The “500Hz Limit Model” limits the maximum frequency up to 500Hz under the “Three-phase output”.
★ PCR-LE2 Series 500Hz Limit Model
The PCR-LE Series offers the type on each model that limits the maximum output frequency up to 500 Hz.
DC mode output ratings, AC+DC mode (for Single-phase and Single-phase Three-wire output only)
Item/Model | PCR6000LE2 | PCR9000LE2 | PCR12000LE2 | PCR18000LE2 | PCR27000LE2 | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | ||
Phase voltage (output L range, output H range)*2 | ±1.4 V to ±212 V / ±2.8 V to ±424 V | ||||||||||
Voltage setting range | -215.5 V to +215.5 V / -431.0 V to +431.0 V | ||||||||||
Voltage setting accuracy (output L range, output H range) *10 | ± (0.05 % of set + 0.05 V / 0.1 V) | ||||||||||
Max. current*4 | Single phase, Single phase 3-wire andThree-phase, L range, H range | 42 A, 21 A · 14 A, 7 A | 63 A, 31.5 A · 21 A, 10.5 A | 84 A, 42 A · 28 A, 14 A | 126 A, 63 A · 42 A, 21 A | 189 A, 94.5 A · 63 A, 31.5 A | |||||
Max. instantaneous current*11 | Max. current (rms) × 3.6 | ||||||||||
Power capacity | Single phase, Single phase 3-wire, Three-phase | 4.2 kW · 2.8 kW | 6.3 kW · 4.2 kW | 8.4 kW · 5.6 kW | 12.6 kW · 8.4 kW | 18.9 kW · 12.6 kW |
*2 L/H range can be changed by means of a switch on the front panel. Resolution: 0.1V
*4 When the maximum voltage is between 1 V and 100 V (L range) or 2 V and 200 V (H range) and the load power factor is between 0.8 and 1.When the output phase voltage is between 100 V and 150 V or 200 V and 300 V (AC mode) or ±100 V and ±212 V or ±200 V and ±424 V (DC mode), the output current is reduced by the output phase voltage.
When the load power factor is between 0 and 0.8, the output current is reduced by the load power factor. (AC mode) When the output frequency is between 1 Hz and 40 Hz, the output current is reduced by the output frequency. (AC mode) *10 With no load at room temperature
*11 Limited by the rated output current’s rms value
Output voltage stability
Item/Model | PCR6000LE2 | PCR9000LE2 | PCR12000LE2 | PCR18000LE2 | PCR27000LE2 | |||||
---|---|---|---|---|---|---|---|---|---|---|
3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | |
Line regulation(With respect to changes in the rated range) | Within ±0.1 % | |||||||||
Line regulation(With respect to 0 % to 100 % changes in the rating)*12 | ±0.3 V | ±0.5 V | ||||||||
Output frequency variation in AC mode(Between 40 Hz and 999.9 Hz)*13 | Within ±0.5 % | Within ±1 % | ||||||||
Ripple noise in DC mode(5 Hz to 1 MHz components) | 0.25 Vrms or less | 0.5 Vrms or less | ||||||||
Ambient temperature variation(With respect to changes in the rated range)*14 | 100 ppm/ °C (TYP) |
*12 When the output phase voltage is between 80 V and 150 V (L range) or 160 V and 300 V (H range) and the load power factor is 1. At the output terminal block. When the response mode is set to MEDIUM.(There is no F mode)
*13 When the output phase voltage is between 80 V and 150 V (L range) or 160 V and 300 V (H range) and the load power factor is 1. This is the output line regulation with 200 Hz as the reference. When the response mode is set to MEDIUM.(There is no F mode)
*14 When the output phase voltage is 100 V or 200 V and the output current is 0 A.
Output frequency stability, output voltage waveform distortion ratio, output voltage response speed, efficiency
Item/Model | PCR6000LE2 | PCR9000LE2 | PCR12000LE2 | PCR18000LE2 | PCR27000LE2 | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | ||
Output frequency stability(With respect to changes in all rated ranges) | Within ±5×10– 5, Setting accuracy : Within ±1×10– 4 | ||||||||||
Output voltage waveform distortion ratio*15 | 0.3 % or less | 0.5% or less | |||||||||
Output voltage response speed*16 | 30 μs (TYP) | 50μs (TYP) | |||||||||
Efficiency*1 | 58 % or more | ||||||||||
Phase difference of the output phase voltage *17 | Resolution | 1deg | |||||||||
Accuracy | Within ± (0.4° + f0×1.8×10– 3) deg f0 is the output frequency *18 |
*1 When the output phase voltage is 100 V or 200 V, the output current is the rated value, the load power factor is 1, and the output frequency is between 40 Hz and 999.9 Hz. *15 When the output phase voltage is between 80 V and 150 V (L range) or 160 V and 300 V (H range) and the load power factor is 1. When the response mode is set to MEDIUM.(There is no F mode) *16 When the output phase voltage is 100 V or 200 V, the load power factor is 1, and the output current changes from 0 A to the rated value and from the rated value to 0 A. *17 Phase difference between output voltages (phase voltages) when each phase is considered along with the neutral point.
Meters (fluorescent display)
Item/Model | PCR6000LE2 | PCR9000LE2 | PCR12000LE2 | PCR18000LE2 | PCR27000LE2 | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | |||
Voltmeter *19 *20 | Resolution | RMS,AVE Display mode | 0.1 V | |||||||||
Accuracy | RMS,AVE Display mode | Within ± (1 % of rdng + 2 digits) (10 V to 848 V and at room temperature) | ||||||||||
Ammeter *19 *20 | Resolution | RMS,AVE Display mode Single phase · Poly phase | 0.1A · 0.01 A | 0.1 A | 0.1 A / 1 A · 0.1 A | |||||||
Accuracy | RMS Display mode | Within ± (1% of reading + 2digits) (5 % of the max. rated current to max. rated current and at room temperature) | ||||||||||
Wattmeter*20 | Resolution | Single phase · Poly phase | 1 W · 0.1 W / 1 W | 1 W | 1 W / 10 W | |||||||
Accuracy | Within ± (1 % of reading + 3digits) (10 % of the rated power capacity to the rated power capacity, when the load power factor is 1, and at room temperature.) | |||||||||||
Frequency meter*21 | Resolution | 0.01 Hz / 0.1 Hz |
*19 With the true rms display, a waveform with a crest factor of 3 or less.
*20 When the output frequency is between 45 Hz and 65 Hz.
General
Item/Model | PCR6000LE2 | PCR9000LE2 | PCR12000LE2 | PCR18000LE2 | PCR27000LE2 | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | 3P3W200V | 3P4W400V | |||
Insulation resistance | Between input and chassis, output and chassis, input and output | 500 Vdc, 10 MΩ or more | ||||||||||
Withstanding voltage | Between input and chassis, output and chassis, input and output | 1.5 kVac for 1 minute | ||||||||||
Circuit method | Linear amplifier system | |||||||||||
Environmental conditions | Operating temperature range / Storage temperature range | 0 °C to +50 °C / -10 °C to +60 °C | ||||||||||
Operating humidity range / Storage humidity range | 20 % rh to 80 % rh (no condensation) / 90 % rh or less (no condensation) | |||||||||||
Weight | Approx.140 kg (308.6 Ibs) | Approx.190kg (418.8 Ibs) | Approx.350 kg (771.6 Ibs) | Approx.480 kg (1058.2 Ibs) | Approx.630 kg (1388.9 Ibs) | |||||||
Input terminal | Input terminal board [3φ] | M8 | M5 | M5 | M8 | M8 | M8 | |||||
Output terminal | Output terminal board Single phase · Single phase 3-wire,Three-phase 4-wire | M8 · M5 | M8 · M8 | |||||||||
Input power cord [Sold separately option] | Type | single-core cable | Required for the installation work, contact local distributor. | |||||||||
The number | 3 pc | 4 pc | 5 pc | 4 pc | 5 pc | |||||||
Conductor cross section/Length | 14mm2/3m | 8mm2/3m | 5.5mm2/3m | 14mm2/3m | 5.5mm2/3m | |||||||
Accessories | Setup guide | 1 copy | ||||||||||
Quick Reference | 1 each for English and Japanese | |||||||||||
Safety information | 1 copy | |||||||||||
CD-ROM(User’s manual) | 1 disc | |||||||||||
Heavy Duty Warning Seals | 1 copy | – | ||||||||||
Other | Electromagnetic compatibility (EMC) | EMC Directive 2014/30/EU. EN61326-1. EN 55011 The maximum length of all cables and wires connected to the PCR-LE Series must be less than 3 m. | – | |||||||||
Safety | Low Voltage Directive 2014/35/EU, EN61010-1 (Class I, Pollution Degree2) | IEC 61010-1 (Class I, Pollution Degree2) |
Limit Values and Protection Functions
Item/Model | PCR6000LE2 | PCR9000LE2 | PCR12000LE2 | PCR18000LE2 | PCR27000LE2 | ||
---|---|---|---|---|---|---|---|
Voltage | AC voltage upper limit AC voltage lower limit | 0.0 V to 305.0 V | |||||
DC voltage upper limit DC voltage lower limit | -431.0 V to +431.0 V | ||||||
Output overvoltage protection AC/AC+DC mode | 0.0 V to 474.1 V | ||||||
Output overvoltage protection DC mode | -474.1 V to +474.1 V | ||||||
Output undervoltage protection AC/AC+DC mode | 0.0 V to 474.1 V | ||||||
Output undervoltage protection DC mode | -474.1 V to +474.1 V | ||||||
Resolution | 0.1 V | ||||||
Frequency | Upper limit Lowerlimit | 1 Hz to 999.9 Hz, 500 Hz LMT model: 1 Hz to 500 Hz (Three-phase output) | |||||
Resolution | 0.01 Hz (1.00 Hz to 100.0 Hz), 0.1 Hz (100.0 Hz to 999.9 Hz) | ||||||
Current | Current limit *1 AC mode | Single-phase output | 6.00A to 66.00A | 9.00A to 99.00A | 12.00A to 132.0A | 18.00A to 198.0A | 27.00A to 297.0A |
Single-phase three-wire output Three-phase output | 2.00A to 22.00A | 3.00A to 33.00A | 4.00A to 44.00A | 6.00A to 66.00A | 9.00A to 99.00A | ||
Current limit *1 DC/AC+DC mode | Single-phase output | 4.20A to 46.20A | 6.30A to 69.30A | 8.40A to 92.40A | 12.60A to 138.6A | 18.90A to 207.9A | |
Single-phase three-wire output Three-phase output | 1.40A to 15.40A | 2.10A to 23.10A | 2.80A to 30.80A | 4.20A to 46.20A | 6.30A to 69.30A | ||
Positive peak current limit *2 | Single-phase output | 6.00A to 264.0A | 9.00A to 396.0A | 12.00A to 528.0A | 18.00A to 792.0A | 27.00A to 1188A | |
Single-phase three-wire output Three-phase output | 2.00A to 88.00A | 3.00A to 132.0A | 4.00A to 176.0A | 6.00A to 264.0A | 9.00A to 396.0A | ||
Negative peak current limit *2 | Single-phase output | -6.00A to -264.0A | -9.00 A to -396.0 A | -12.00 A to -528.0 A | -18.00 A to -792.0 A | -27.00 A to -1188 A | |
Single-phase three-wire output Three-phase output | -2.00A to -88.00A | -3.00 A to -132.0 A | -4.00 A to -176.0 A | -6.00 A to -264.0 A | -9.00 A to -396.0 A | ||
Resolution *3 | 0.01 A (0.35 A to 100.0 A) , 0.1A (100.0 A to 1000 A) , 1 A (1000 A to 1188 A) |
*1 The current that can actually be supplied is 1.1 times the rated current or the current limit, whichever is less. *2 The current that can actually be supplied is the maximum peak current or the current limit, whichever is less. *3 You can set the current in 0.01 A/ 0.1 A/ 1 A steps, but it may not change at this resolution depending on the relationship with the internal D/A resolution.
Options
Input power cable
For PCR6000LE2
For PCR6000LE2(3P3W input)/PCR9000LE2(3P3W input)
For PCR6000LE2(3P4W input)/PCR9000LE2(3P4W input)
Interface
For GPIB
for USB
For LAN/LXI
Analog signal interface boards※3 ※4 ※5 ※6
IEC Dip·Simulator
Line Impedance Network
Extension cable for control panel
Base Hold Angles
1 PCR500LE and PCR1000LE cannot be used. 2 Up to 5 units can be used in parallel. (Power within 27kVA) *3 Input waveforms are amplified and output as they are. 4 Multi-output models (6000LE2, 9000LE2) cannot amplify input waveforms in multi-phase output mode. 5 The output AC voltage value can be varied according to the input DC signal. 6 The multi-output models (6000LE2, 9000LE2) cannot control the amplitude in the multi-phase output mode.
Software
More convenient and easy to use! Appliquation software to help you with your exams
Product Catalog
2D CAD
PCR6000LE2
PCR9000LE2
PCR12000LE2
PCR18000LE2
PCR27000LE2